HI-97115C Marine Master Waterproof Wireless Multiparameter Photometer Kit
HI-97115C
A great kit comprising a compact and versatile Marine multiparameter photometer designed to accurately determine the eight parameters listed. It is suitable for use in the field or Lab/benchtop environments.
*The lead image of the kit is for illustration purposes only. Contents of the kit may differ from other photometers in the series.
HI-97115C Marine Master Waterproof Wireless Multiparameter Photometer Kit
For use in aquariums and marine biology applications, this meter measures Marine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate Low Range, Nitrite Ultra Low Range, and Phosphate Ultra Low Range.
The kit contains:
- HI-97115 photometer
- Carrying case
- Sample cuvettes x 2
- Sample caps x 2
- Marine pH reagent - 30mL dropper x 1
- Marine Alkalinity reagent – 30ml bottle x 1
- Marine Ammonia starter kit – reagent A and C - 1 of each x 30ml dropper, plus reagent B x 25 tests
- Marine Calcium starter kit – Reagent A 30ml bottle, reagent B x 25 tests
- Marine Magnesium starter kit – reagent A 120ml bottle, Magnesium indicator reagent x 25 tests
- Marine Nitrate High Range reagent x 25 tests
- Marine Nitrite ULR reagent x 25 tests
- Marine phosphate ULR x 25 tests
- 1mL graduated syringe with tip x 2
- Mini-pipette with tip x 1
- 3 ml Pasteur pipette x 2
- 5mL syringe and tip x 1
- 5ml syringe (blue printing) with tip x 1
- 1.5V AA alkaline batteries x 3
- Cloth for wiping cuvettes
- Scissors
- Instrument quality certificate
- Quick reference guide
(Please note: not all reagents and the Cal Check standard are included in this kit, so check your testing requirements are covered when ordering. See specification table to choose further reagents. Additional costs apply.)
Please download the Safety Datasheet(s) which provide more detail on the reagents before use; click on the link in the “safety data sheets” paragraph below.
About the photometer
The HI-97115 can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.
Key features
- Backlit LCD – The 128 x 64 pixel LCD allows for a simplified user interface
- Battery status indicator and auto-shut off – The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order to conserve battery life
- Method and parameter – Chosen parameter and method used are displaying along with the reading
- Large cuvette size – The sample cell fits a round glass cuvette with a 25mm path length. This allows the light to pass through more of the sample ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette.
- Virtual keys
- Compact size – Measures 142.5mm x 102.5mm and 50.5mm thick.
- Menu available at the touch of a button
- Dedicated help key – this provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.
Hanna Lab App
When the photometer is paired with a compatible smart device, it adds an enhanced user experience to the photometer. You can name samples and add notes, view logged detail such as date and time, share logged data in various formats, and control meter settings.
More key features:
- Waterproof and floats – IP67 meter design
- Option to select measurement location for better tracking consistency
- CAL CheckTM validation and calibration – step-by-step screen guides through the validation process and user calibration. GLP data displays the last calibration date.
- Backlit LCD and on-screen help
- Built-in reaction timer that ensures consistency between tests
- On-screen tutorial mode with animations – this includes steps required for sample preparation, the required reagents and quantities. Enabled via the setup menu.
- Auto-data logging features to easily record water testing results – up to 200 individual measurements (data points). When the log is full, the instruments rewrites the oldest data point
Positive locking system ensures cuvettes are placed into the holder in the same position every time
HI-97115 is supplied with sample cuvette (2pcs), sample cuvette caps (2pcs), 1.5V AA alkaline batteries (3 pcs), instrument quality certificate, and quick reference guide.
Cal Check standards and reagents are sold separately.
Safety Data Sheets
Access safety data sheets online here. When using any form of chemical, it is important you download the relevant safety datasheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety datasheets and download a copy by following the link below.
Please note that the '-' in HI- products should be removed from all searches to find the correct information.
Read More
Alkalinity, Marine Range | 0.0 to 20.0 dkH 0 to 357 ppm (as CaCo3) | |
Alkalinity, Marine Resolution | 0.1 dkH | |
Alkalinity, Marine Accuracy | ±0.3 dKH ±5 % of reading at 25 °C ±5 ppm ±5 % of reading at 25 °C | |
Alkalinity, Marine Method | Colorimetric Method - The reaction causes a distinctive range of colours from yellow to greenish blue to develop | |
Ammonia, Marine Range | 0.00 to 2.50 ppm (as NH₃) | |
Ammonia, Marine Resolution | 0.01 ppm | |
Ammonia, Marine Accuracy | ±0.05 ppm ±5% of reading at 25°C | |
Ammonia, Marine Method | Adaptation of the Salicylate Method | |
Ammonia, Marine LED | 610 nm | |
Calcium, Marine Range | 200 to 600 ppm | |
Calcium, Marine Resolution | 1 ppm | |
Calcium, Marine Accuracy | ±6 % of reading at 25 °C | |
Calcium, Marine Method | Adaptation of the Zincon Method | |
LED | 610nm | |
Marine Magnesium | ||
Range | 1000 to 1800 ppm (as Mg2+) | |
Resolution | 5 ppm | |
Accuracy | ±5% of reading at 25 °C | |
Method | Adaptation of the Colorimetric EDTA Method using calmagite indicator | |
LED | 610 nm | |
Nitrate Range | 0.00 to 5.00 ppm (as No3¯) 0.0 to 75.0 ppm (as No3¯) | |
Nitrate Resolution | 0.01 ppm | |
Nitrate Accuracy | ±0.25 ppm ±2% of reading at 25°C | |
Nitrate Method | Zinc reduction method | |
LED | 525nm | |
Nitrite, Marine ULR Range | 0 to 200 ppb (as No2¯-N) | |
Nitrite, Marine ULR Resolution | 1 ppb | |
Nitrite, Marine ULR Accuracy | ±10 ppb ±4 % of reading at 25 °C | |
Nitrite, Marine ULR Method | Adaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample. | |
LED | 525nm | |
Marine pH Range | 6.3 to 8.6 pH | |
pH Resolution | 0.1 pH | |
pH Accuracy | ±0.2 pH of reading at 25°C | |
pH Method | Colorimetric Adaptation of the Phenol Red Method | |
LED | 525nm | |
Phosphate, LR Range | 0.00 to 0.90 ppm | |
Phosphate, LR Resolution | 0.01 ppm | |
Phosphate, LR Accuracy | ±0.02 ppm ±5 % of reading at 25 °C | |
Phosphate, LR Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample. | |
LED | 610nm | |
Light Source | light emitting diode (LED) | |
Light Detector | Silicon photocell | |
Bandpass Filter Bandwidth | 8 nm | |
Bandpass Filter Wavelength Accuracy | ±1.0 nm | |
Logging | 200 readings | |
Power Supply | 1.5 V AA Alkaline (3 pcs.) | |
Battery Life | > 800 measurements (without backlight) | |
Auto-off | After 15 minutes of inactivity | |
Environment | 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non serviceable | |
Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") | |
Weight | 380 g (13.4 oz.); with batteries | |
Casing | IP67 rated, floats | |
Warranty | 2 years |
Reagents, CAL Check Standards & accessories - buy separately: |
Reagent sets | |
HI-758‑26 | Marine Calcium Reagent - 25 tests |
HI-764‑25 | Marine Nitrite ULR Reagent - 25 tests |
HI-772‑26 | Marine Alkalinity Reagent - 25 tests |
HI-774‑25 | Marine Phosphate ULR Reagent - 25 tests |
HI-780‑25 | Marine pH Reagent - approximately 100 tests |
HI-781‑25 | Marine Nitrate LR Reagent - 25 tests |
HI-782‑25 | Marine Nitrate HR Reagent - 25 tests |
HI-783-25 | Marine Magnesium Reagents - 25 tests |
HI-784-25 | Marine Ammonia Reagent - 25 tests |
HI-97105‑11 | CAL Check™ standards for HI-97105 & HI-97115 - cuvette kit |
Other Accessories | |
HI-70436M | Deionized water (230 mL) |
HI-7101419 | Blue carrying case for HI-97115 |
HI-731318 | Cloth for wiping cuvettes (4 pcs.) |
HI-731360 | Glass cuvette with cap (2 pcs.) |
HI-740270 | 10 mL syringe with Luer Lock (1 pc.) |
HI-740271 | Filter holder with Luer Lock (1 pc.) |
HI-740272 | 16 gauge blunt needle (6 pcs.) |
HI-740273 | Marine Nitrate LR measurement kit (1 pc.) |
HI-740228 | Filter disc (25 pcs) |
HI-93703‑50 | Cuvette cleaning solution (230 mL) |
(Please note: not all reagents and the Cal Check standard are included in this kit, so check your testing requirements are covered when ordering. See specification table to choose further reagents. Additional costs apply.)