This meter is a waterproof test that offers high accuracy pH, EC/TDS, and temperature measurements in a single tester.
HI-981304 pH/EC/TDS Combo Tester
There will be no need to keep swapping between meters for your routine measurements with this floating, waterproof combination tester. It has an easy-to-read LCD and automatic shut-off. pH and EC/TDS readings are automatically temperature compensated.
The EC/TDS conversion factor is user-selectable, as well as the temperature compensation coefficient (β).
Features
- Waterproof – designed to float if accidentally dropped in water
- Automatic Temperature Compensation – All readings are compensated for variations in temperature and temperature is displayed along with the pH reading.
- Stability indicator – Meter displays a tag that will disappear when the reading has achieved stability
- Hold button – Freezes reading on the display to allow recording of measurement
- BEPS (Battery Error Prevention System) – Meter will automatically shut off if there is not enough power to get an accurate measurement
- Battery % level at start up
- Low Battery Indicator
- Automatic Shut-Off – The meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto off feature can be disabled.
High accuracy EC/TDS Graphite Probe
The graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.
Replaceable pH electrode cartridge
The combo features an easy to replace pH electrode. The sturdy, snap-in connector means there are no pins which could bend or break.
Protective Cap
The protective cap features an internal cup that can be filled with storage solution to keep the pH sensor moist.
Calibrate right in the sachets
Calibration can be performed directly into the solution sachets.
Supplied complete
Supplied with all the tools necessary to start performing tests.
Keep in compliance with HSG282
Do you have a holiday home or offer your customers commercial hot tubs or spa pools? If you want to be HSG282 compliant, Hanna Instruments pH testers are an ideal solution. Our simple-to-use instruments make it effortless to take twice-daily pH readings for full HSG282 compliance, protecting you and your business against legal risk and potential negative reputation.
Since 2017, the HSE has provided clear guidelines to help businesses avoid guest and employee sickness. Legionella, e-coli and a range of other nasty pathogens thrive in hot tubs and pools' warm, agitated waters when they are not properly sanitised.
Measuring pH with a suitable HSG282 pH tester ensures you meet those guidelines, keeping your customers safe and your business risk-free. The HI-981304 allows you to easily read pH alongside TDS, providing clear and accurate information to help you keep your hot tub water balanced.
Need to know more about HSG282? Our complete guide is the best place to start, covering everything from the best HSG282 pH testers to the processes to follow.
Read More
pH Range | 0.00 to 14.00 | |
pH Resolution | 0.01 pH | |
pH Accuracy | ±0.05pH | |
Conductivity Range | 0.00 to 20.00 mS/cm | |
Conductivity Resolution | 0.01 mS/cm | |
Conductivity Accuracy | ±2% F.S. | |
TDS Range | 0.00 to 10.00 g/L (ppt) | |
TDS Resolution | 0.01 ppt (g/L) | |
TDS Accuracy | ±2% F.S. | |
Temperature Range | 0.0 to 60.0°C | |
Temp Resolution | 0.1°C | |
Temp Accuracy | ±0.5°C | |
Additional specifications | ||
EC/TDS calibration | Automatic, one point at 12.88 mS/cm or 6.44 ppt (g/L) | |
pH Calibration | Automatic, one or two point with two sets of standard buffers | |
Temp compensation | pH automatic; EC/TDS automatic with β adjustable from 0.0 to 2.4%/°C | |
TDS conversion factor | 0.45 to 1.00 | |
pH electrode replacement | HI-73127 | |
Battery life & type | 1.5V (4) approx. 300 hours of continuous use; auto off after 8 minutes of non-use | |
Environment | -5 to 50°C; RH max 100% | |
Dimensions | 163 x 40 x 26mm | |
Weight | 100 g | |
Ordering information | Supplied with HI-73127 pH electrode, electrode removal tool, protective cap, pH 4.01 buffer solution sachet, pH 7.01 buffer solution sachet, 12888 µS/cm conductivity standard solution sachet, 6.4 ppt TDS standard sachet, pH electrode cleaning solution sachet, electrode storage solution sachet, batteries, and instructions. |