HI-83326-02 Multi-parameter photometer with pH meter for Swimming Pools and Spas
In Stock 3 Items available
HI-83326-02
One meter can be used for both photometric and pH measurements. HI-83326 is a compact, multi-parameter photometer for use in pool and spa applications.
HI-83326 Pool and Spa Photometer with pH
Advanced optical system - Unparalleled performance from a benchtop photometer.
One meter can be used for both photometric and pH measurements. HI-83326 is a compact, multi-parameter photometer for use in pool and spa applications. The meter is one of the most advanced photometers available with an innovative optical design which utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.
The HI-83326 has 12 different programmed methods measuring 11 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves.
Pool and spa parameters include alkalinity, free chlorine, nitrite, and phosphate which are critical to maintaining a healthy system.
To save valuable laboratory benchtop space, the HI-83326 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.
Made with the pool and spa industry in mind, a basic necessity of pool water treatment is to maintain the water in a safe and pleasant condition for the swimmers. In pool and spa water treatment, disinfection is essential to rid the pool of bacteria and control nuisance organisms like algae which may occur in the pool, spa, filtration equipment, or piping. There are a number of available disinfectant compounds including chlorine, bromine, and ozone. In order to achieve ideal water conditions, water requires testing on a daily and sometimes hourly basis to ensure there is enough residual disinfectant and to maintain pH levels. Equally important is calcium hardness and alkalinity; these levels should be monitored weekly to ensure the pool or spa water is well balanced to avoid corrosion and scale formation.
A digital pH electrode input allows the user to measure pH by a traditional glass electrode.
The HI-83326 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.
Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.
Key features:
- Advanced optical system with brighter, long-lasting LED light source
- Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
- Built-in Reaction Timer for Photometric Measurements
- Absorbance mode - concentration versus absorbance
- Units of Measurement plus chemical form displayed
- Result conversion at the touch of a button
- Cuvette cover
- pH and temperature measurement with a single digital probe
- Good Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability
- CAL Check alerts user to potential problems during the calibration process
- Data Logging - Up to 1000 photometric and pH readings can be stored.
- Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.
- Battery Status Indicator
- Error Messages
High Efficiency LED Light Source
An LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.
High Quality Narrow Band Interference Filters
The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.
Reference Detector for a Stable Light Source
A beam splitter is used as part of the internal reference system of the HI-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.
Large Cuvette Size
The sample cell of the HI-83308 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.
Focusing Lens for Greater Light Yield
Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.
Input Channels1 pH electrode input and 3 photometer wavelengths
HSG282 compliance? Covered
As a multi-purpose meter for pools and hot tubs, the HI-83326-02 is your ideal instrument for complying with the HSE's 2017 HSG282 guidelines. This legislation protects businesses by putting steps into place that prevent serious customer and employee sickness. In heated, agitated water, pathogens like legionella and e-coli can thrive.
Complying with HSG282 pH testing regulations is one way to gain peace of mind and ensure your business is safe from risk. This multiparameter meter's unique functionality helps you achieve that goal, allowing you to accurately test pH in water twice daily with results you can rely on. With everything covered in one instrument, taking measurements and maintaining records to a high standard is easier than ever.
Measuring pH is integral for achieving proper sanitation in your pool chemistry. Accurately dosing your water is an impossible task without precise pH measurements. The HI-83326-02 offers extremely accurate pH testing results, helping you to comply with HSG282 and keep your hot tubs and spa pools clean and clear.
Our complete HSG282 guide covers everything you’ve ever wanted to know about this UK legislation. Read all about it here today.
Read More
ALKALINITY
Alkalinity Range | Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3) | |
Alkalinity Resolution | 1 mg/L | |
Alkalinity Accuracy | ±5 mg/L ±5% of reading | |
Alkalinity Method | Bromocresol Green | |
Reagent code | HI-775-25 25 tests |
BROMINE
Bromine Range | 0.00 to 8.00 mg/L (as Br2) | |
Bromine Resolution | 0.01 mg/L | |
Bromine Accuracy | ±0.08 mg/L ±3% of reading | |
Bromine Method | DPD method | |
Reagent code | HI-93716-01 |
CHLORINE DIOXIDE
Chlorine Dioxide Range | 0.00 to 2.00 mg/L (as ClO2) | |
Chlorine Dioxide Resolution | 0.01 mg/L | |
Chlorine Dioxide Accuracy | ±0.10 mg/L ±5% of reading | |
Chlorine Dioxide Method | Adaptation of the Chlorophenol Red method. | |
Reagent code | HI-93738-01 |
CHLORINE, FREE
Free Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) | |
Free Chlorine Resolution | 0.01 mg/L | |
Free Chlorine Accuracy | ±0.03 mg/L ±3% of reading | |
Free Chlorine Range | 0.00 to 5.00 mg/L (as Cl2) | |
Free Chlorine Resolution | 0.01 mg/L | |
Free Chlorine Accuracy | ±0.03 mg/L ±3% of reading | |
Chlorine Method | DPD | |
Reagent code | HI-93701-01 |
CHLORINE, TOTAL
Total Chlorine Range | 0.00 to 5.00 mg/L (as Cl-) | |
Total Chlorine Resolution | 0.01 mg/L | |
Total Chlorine Accuracy | ±0.03 mg/L ±3% of reading | |
Chlorine Method | DPD | |
Reagent code | HI-93711-01 |
COPPER
Copper Range | High range: 0.00 to 5.00 mg/L (as Cu2+) | |
Copper Resolution | 0.01 mg/L | |
Copper Accuracy | High Range ±0.02 mg/L ±4% of reading | |
Copper Method | Adaptation of the EPA bicinchoninate method | |
Reagent code | HI-93702-01 |
CYANURIC ACID
Cyanuric Acid Range | 0 to 80 mg/L (as CYA) | |
Cyanuric Acid Resolution | 1 mg/L | |
Cyanuric Acid Accuracy | ±1 mg/L ±15% of reading | |
Cyanuric Acid Method | Adaptation of the turbidimetric method | |
Reagent code | HI-93722-01 |
HARDNESS, CALCIUM
Hardness, Calcium Range | 0.00 to 2.70 mg/L (as CaCO3) | |
Hardness, Calcium Resolution | 0.01 mg/L | |
Hardness, Calcium Accuracy | ±0.11 mg/L ±5% of reading | |
Hardness, Calcium Method | Calmagite method | |
Reagent code | HI-93720-01 |
IRON
Iron Range | High Range: 0.00 to 5.00 mg/L (as Fe) | |
Iron Resolution | 0.01 mg/L | |
Iron Accuracy | High Range: ±0.04 mg/L ±2% of reading | |
Iron Method | High Range: Phenanthroline method | |
Reagent code | HI-93721-01 |
NITRATE
Nitrate Range | 0.0 to 30.0 mg/L (as NO3-- N) | |
Nitrate Resolution | 0.1 mg/L | |
Nitrate Accuracy | ±0.5 mg/L ±10% of reading | |
Nitrate Method | Cadmium reduction method | |
Reagent code | HI-93728-01 |
OZONE
Ozone Range | 0.00 to 2.00 mg/L (as O3) | |
Ozone Resolution | 0.01 mg/L | |
Ozone Accuracy | ±0.02 mg/L ±3% of reading | |
Ozone Method | DPD Method | |
Reagent code | HI-93757-01 |
pH
pH range | 6.5 to 8.5 pH | |
pH Resolution | 0.1 pH | |
pH Accuracy | ±0.1 pH | |
pH Method | Phenol red method | |
Reagent code | HI-93710-01 |
PHOSPHATE
Phosphate Range | Low Range: 0.00 to 2.50 mg/L (as PO43-) | |
Phosphate Resolution | 0.01 mg/L | |
Phosphate Accuracy | Low Range: ±0.04 mg/L ±4% of reading | |
Phosphate Method | Low Range: Ascorbic Acid method | |
Reagent code | HI-93713-01 |