+44 (0)1525 850 855
Order before 4pm for same day dispatch Weekdays only
Menu

In Stock 1 Item available

HI-97714

HI-97714 Cyanide Portable photometer has an advanced optical system that uses a Light Emitting Diode (LED) and a narrow band interference filter that allows for accurate and repeatable readings.

Cyanide

£490.50 (exc.VAT)
£588.60 (tax incl.)
Accessories
Reference
Price
Quantity
Full Description Specification Manuals

Each HI-97714 is delivered in a cardboard box and is supplied with:

  • Sample cuvette (2 pcs.)
  • Sample cuvette cap (2 pcs.)
  • Plastic stopper (2 pcs.)
  • 1.5V AA Alkaline batteries
  • Instrument quality certificate
  • Instruction manual

The HI-97714 is an auto-diagnostic portable photometer that benefits from Hanna’s years of experience as a manufacturer of analytical instruments. It has an advanced optical system that uses a Light Emitting Diode (LED) and a narrow band interference filter that allows for accurate and repeatable readings.

The optical system is sealed from outside dust, dirt and water. The meter uses an exclusive positive-locking system to ensure that the cuvettes are placed into the holder in the same position every time.

With the CAL Check™ functionality, users are able to validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check cuvettes are made with NIST traceable standards.

The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities.

The HI-97714 meter measures the cyanide content in water samples in the 0.000 to 0.200 mg/L (ppm). The method is an adaptation of the Pyridine-Pyrazalone Method.

The HI-97714 photometer is a compact and versatile meter suitable for field or bench measurements, featuring a:

  • Sophisticated optical system
  • Meter validation using certified CAL Check cuvettes
  • Tutorial mode guides the user step-by-step
  • Auto logging
  • Waterproof IP67, floating case
  • GLP features

The internal reference system (reference detector) of the HI-97714 photometer compensates for any drifts due to power fluctuations or ambient temperature changes, providing a stable source of light for your blank (zero) measurement and sample measurement.

LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps have poor blue/violet light output.

Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

A focusing lens collects all of the light that exits the cuvette, eliminating errors from cuvette imperfections and scratches, eliminating the need to index the cuvette.

REQUIRED REAGENTS

  • HI-93714A-0 Cyanide Reagent A
  • HI-93714B-0 Cyanide Reagent B
  • HI-93714C-0 Cyanide Reagent C

REAGENT SETS

  • HI-93714-01 Cyanide Reagent - 100 tests
  • HI-93714-03 Cyanide Reagent - 300 tests

About Cyanide

The term cyanide refers to all of the CN groups in cyanide compounds that can be determined as the cyanide ion CN.

Originating in water, primarily from metallurgical and galvanic industrial plants, cyanide is highly toxic to the human nervous system.

Read More

Range0.000 to 0.200 mg/L (ppm) (as CN-)
Resolution0.001 mg/L
Accuracy±0.005 mg/L ±3% of reading
MethodAdaptation of the Standard methods for the examination of Water and Wastewater, 18th edition, pyridine-pyrazolone Method
Photometer/Colorimeter Light SourceLight emitting diode
Photometer/Colorimeter Light DetectorSilicon photocell with narrow band interference filter @ 610 nm
Bandpass Filter Bandwidth8 nm
Bandpass Filter Wavelength Accuracy±1.0 nm
Cuvette Typeround, 24.6 mm diameter (22 mm inside)
GLPDate, time of last calibration
Display128 x 64 pixel B/W LCD with backlight
Logging Typeautomatic logging
Logging Memory50 measurement
Battery Type/Life1.5V AA battery (3 pcs.) / > 800 measurements (without backlight)
Automatic Shut-OffAfter 15 minutes of inactivity (30 minutes before a READ measurement)
Environment0 to 50°C (32 to 122°F); relative humidity: 100% (IP 67, floating case)
Weight380g with batteries
Dimensions142.5 x 102.5 x 50.5 mm
Ordering InformationHI-97714 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.
Reagents and CAL Check StandardsHI-97714-11 CAL Check Standard Cuvettes
HI-93714-01 Reagents 100 tests
HI-93714-03 Reagents 300 tests