Hanna HI-729 Fluoride Low Range Handheld Colorimeter, Checker®HC

In Stock 4 Items available

HI-729

The HI-729 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure fluoride.

Fluoride

£83.20 (exc.VAT)
£99.84 (tax incl.)
Accessories
Reference
Price
Quantity
Full Description Specification Manuals

Fluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.


The HI-729 pocket checker is a simple and accurate way to measure low ranges of fluoride.

Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva which reduces the rate at which tooth enamel de-mineralises and increases the rate at which it re-mineralises in the early stages of cavities.

A 1994 World Health Organisation expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.


Key features

      • Accurate and easy to use
      • Adaptation of SPADNS method
      • ±0.05 ppm ±5% of reading
      • 0.01 ppm resolution
      • Designed to work with Hanna reagents
      • Large easy to read digits
      • Auto shut-off


Ideal for

      • Water testing
      • Quick on the spot analysis



Supplied with

      • 2 sample cuvettes with caps
      • Reagents for 6 tests (re-ordering information HI-729-26 x 20 tests
      • Syringe with tip
      • 1 x 1.5V AAA battery
      • Instructions



Four steps. One click. Instant Readout.

Step 1  1. ‘Zero’ the Checker®HC with your vial inside

Step 2  2. Place a 10ml water sample into the vial and add your reagent

Step 3  3. Place your vial into your Checker®HC

Step 4  4. Press the button and read the results


Use Calibration Check Set HI-729-11 with the Hi-729 Fluoride Low Range Handheld Colorimeter, Checker®HC.

Use reagent HI-729-26 with the Hi-729 Fluoride Low Range Handheld Colorimeter, Checker®HC, x 20 tests.

Read More

Range0.00 to 2.00 ppm
Resolution0.01 ppm
Accuracy @ 20°C±0.05 ppm ±5% of reading
Light SourceLED @ 575 nm
Light Detectorsilicon photocell
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type(1) 1.5V AAA
Auto-offafter two minutes of non-use and ten seconds after reading
Dimensions81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight64 g (2.25 oz.)
Methodadaptation of SPADNS method