HI-716 Bromine Handheld Colorimeter - Checker HC
In Stock 4 Items available
HI-716
The HI-716 Checker is a simple, accurate, and cost effective way to measure Bromine. Checker®HC is supplied with reagents for 6 tests. Use code HI-716-25 for future purchases.
HI-716 Bromine Handheld Colorimeter - Checker HC
The HI-716 Checker is a simple, accurate, and cost effective way to measure Bromine.
Designed as a more accurate alternative to chemical test kits, the HI-716 provides quick, accurate results in four easy steps.
The HI-716 uses an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample.
Features:
- Small palm-sized design
- Accurate from ±0.1 ppm ±5% of reading
- Dedicated to a single parameter
- Uses a single AAA battery
- Auto Power Off after 10 minutes in inactivity
- Built-in timer for timed reaction readings
Ideal for:
- Water Quality
- Education
- Swimming Pools/Hot Tubs Sanitisation
- Environmental
Ordering information: supplied with sample cuvettes with caps (2), bromine reagent starter kit (6 tests) - re-ordering number: HI-716-25 x 25 tests, battery, instructions and quick start guide.
Four steps. One click. Instant Readout.
1. ‘Zero’ the Checker®HC with your vial inside
2. Place a 10ml water sample into the vial and add your reagent
3. Place your vial into your Checker®HC
4. Press the button and read the results
Use reagents HI-716-25 with the HI-716 Bromine Handheld Colorimeter - Checker®HC, x 25 tests.
Use Calibration Check set HI-716-11 with the HI-716 Bromine Handheld Colorimeter - Checker®HC.
Safety Data Sheets
When using any form of chemical, such as Hanna reagents, it is important you download the relevant safety data sheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety data sheets and download a copy by following the link below.
Please note that the '-' in HI- products should be removed from all searches to find the correct information.
Read More
Range | 0.0 to 8.0 ppm | |
Resolution | 0.1 ppm | |
Accuracy (@25°C/77°F) | ±0.1 ppm ±5% of reading | |
Measurement Method | Colorimetric | |
Light Source | LED @525 nm | |
Light Detector | Silicon photocell | |
Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample. | |
Power Supply | Battery - 1 x 1.5V AAA | |
Power Auto Off | After 10 min. of inactivity | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) | |
Weight | 64 g (2.25 oz.) |