+44 (0)1525 850 855
Order before 4pm for same day dispatch Weekdays only
Menu
Hanna Instruments UK HI-716 Bromine Handheld Colorimeter - Checker®HC

In Stock 2 Items available

HI-716

The HI-716 Checker is a simple, accurate, and cost effective way to measure Bromine. Checker®HC is supplied with reagents for 6 tests. Use code HI-716-25 for future purchases.

0.0 to 8.0 ppm
Bromine

£83.20 (exc.VAT)
£99.84 (tax incl.)
Accessories
Reference
Price
Quantity
Full Description Specification Manuals

HI-716 Bromine Handheld Colorimeter - Checker HC

The HI-716 Checker is a simple, accurate, and cost effective way to measure Bromine.

Designed as a more accurate alternative to chemical test kits, the HI-716 provides quick, accurate results in four easy steps.

The HI-716 uses an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample.

Features:

  • Small palm-sized design
  • Accurate from ±0.1 ppm ±5% of reading
  • Dedicated to a single parameter
  • Uses a single AAA battery
  • Auto Power Off after 10 minutes in inactivity
  • Built-in timer for timed reaction readings

Ideal for:

  • Water Quality
  • Education
  • Swimming Pools/Hot Tubs Sanitisation
  • Environmental

Ordering information: supplied with sample cuvettes with caps (2), bromine reagent starter kit (6 tests) - re-ordering number: HI-716-25 x 25 tests, battery, instructions and quick start guide.

Four steps. One click. Instant Readout.

Step 1  1. ‘Zero’ the Checker®HC with your vial inside

Step 2  2. Place a 10ml water sample into the vial and add your reagent

Step 3  3. Place your vial into your Checker®HC

Step 4  4. Press the button and read the results

Use reagents HI-716-25 with the HI-716 Bromine Handheld Colorimeter - Checker®HC, x 25 tests.

Use Calibration Check set HI-716-11 with the HI-716 Bromine Handheld Colorimeter - Checker®HC.

Read More

Range0.0 to 8.0 ppm
Resolution0.1 ppm
Accuracy (@25°C/77°F)±0.1 ppm ±5% of reading
Measurement MethodColorimetric
Light SourceLED @525 nm
Light DetectorSilicon photocell
MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample.
Power SupplyBattery - 1 x 1.5V AAA
Power Auto OffAfter 10 min. of inactivity
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight64 g (2.25 oz.)