HI-709 Manganese High Range Handheld Colorimeter - Checker HC
In Stock 4 Items available
HI-709
Ideal for plating, the HI-709 high range Manganese Checker is a simple, accurate and cost effective way to measure high ranges of manganese in water. Checker®HC is supplied with reagents for 6 tests. Use code HI-709-25 (25 tests) for future purchases.
HI-709 Manganese High Range Handheld Colorimeter - Checker®HC
The HI-709 high range Manganese Checker is a simple, accurate and cost effective way to measure high ranges of manganese in water.
Designed as a more accurate alternative to chemical test kits, the HI-709 provides quick, accurate results in four easy steps.
HI-709 uses an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method. The reaction between manganese and the reagents cause a pink tint in the sample.
Ideal for
- Water quality
- Education
- Industrial
- Environmental
Key features
- Small palm-sized design
- Accurate from ± 0.02 ppm ±5% of reading
- Dedicated to a single parameter
- Auto power off after 10 minutes of inactivity
- Built-in timer for timed reaction readings
Order Information
The HI-709 Manganese High Range Checker is supplied with sample cuvettes with caps (2), Manganese High reagent starter kit (HI-709-25 reagents for 25 tests), glass cylinders with rubber cap (2), battery, instructions and quick start guide.
You can also buy HI-709-11 Calibration check set. Replacement reagents HI-709-25 Manganese high range reagents 25 tests.
Four steps. One click. Instant Readout.
1. ‘Zero’ the Checker®HC with your vial & water sample inside
2. Take the vial out and add your reagent
3. Place your vial into your Checker®HC
4. Press the button and read the results
Use Reagents HI-709-25 for HI-709 Manganese HR handheld Colorimeter - Checker®HC
Use HI-709-11 Calibration Check Sets for HI-709 Manganese HR handheld Colorimeter - Checker®HC
Read More
Range | 0.0 to 20.0 ppm | |
Resolution | 0.01 ppm | |
Accuracy (@ 25°C) | ± 0.2 ppm ± 5% of reading | |
Light Source | LED @ 525 nm | |
Light Detector | Silicon photocell | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
Battery Type | (1) 1.5V AAA | |
Auto-off | After 10 minutes of non-use | |
Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5") | |
Weight | 64 g (2.25 oz.) | |
Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method. The reaction between manganese and the reagents cause a pink tint in the sample |