HI-981954 Pool Line pH/EC/ ORP multiparameter portable meter supplied with HI-7698195 probe with 4 meter cable
In Stock 2 Items available
HI-981954
This great all-round portable meter measures pH, ORP, EC, TDS, Resistivity, Salinity, Seawater σ and Temperature. Ideal for Pools and Spas, plus other water applications.
The HI-981954 is a waterproof portable logging multiparameter meter that monitors up to 9 different water quality parameters.
The multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged.
The complete system is simple to setup and easy to use.
Key Features
Calibration: Up to a three-point calibration with five standard buffers and one custom buffer available.
pH in mV option: Useful for diagnostics.
GLP data: Offset, slope, date, time and buffers used
Automatically temperature compensated readings
pH or pH/ORP field replaceable sensors: Gel filled and maintenance free plus double junction for reduced contamination of reference cell.
EC/TDS/Resistivity Features
Calibration: Single-point calibration from six standards
Temperature compensation: Automatic Temperature Compensation; Configurable temperature coefficient range from 0.00 to 6.00%/°C; Choice of reference temperatures at 20 or 25°C; Absolute conductivity can be displayed along with the temperature compensated value.
Auto-ranging
Salinity readings: Practical Salinity Scale (PSU) based on conductivity calibration.
Optional shockproof silicon rubber boot: Specially designed to protect your meter from damage or impact – HI-710034 Orange.
About the Backlit Graphic LCD Display
The HI-981954 features a backlit graphic LCD with on-screen help and the capability to display up to nine parameters simultaneously.
The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Waterproof Protection
The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.
GLP Data
HI-981954 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key.
Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
Data Logging
The HI-981954 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours.
Intuitive Keypad
The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data.
The interface is intuitive for any user’s level of experience.
Dedicated Help Key
Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
PC Connectivity
Logged data can be transferred to a Window’s compatible PC with the included HI-920015 micro USB cable and HI9298194 software.
Long Battery Life
The display of the meter has a battery icon indicator to show the remaining power. The meter uses four 1.5V AA batteries that provide up to 360 hours of battery life.
Rugged Custom Carrying Case
The HI-981954 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.
About the Quick Connect Digital Probe and sensors
The HI-7698195 is a multiparameter pH/EC/Temperature probe for use with the HI-981954 portable meter. It features a Quick Connect DIN that makes a waterproof connection with the meter.
It has colour coded, field replaceable sensors that are quick and easy to install with their screw type connectors that are colour coded for easy sensor port identification.
Sensors are automatically recognised by the probe and meter when connected. Any ports not used on the probe will not have the parameter displayed on the meter.
Sensor replacement is quick and easy with field replaceable, screw type connectors that are colour coded for easy sensor identification. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, 20m, and 40m lengths available. It’s rugged, waterproof design makes it ideal for field use.
Quick Calibration
Quick Calibration provides a speedy, single point calibration for pH and conductivity.
Standard pH calibration options are available for calibrating up to three points from a selection of five standard buffers and one custom buffer.
Conductivity calibration is a single point from six standard selections or one custom standard.
Auto-sensor Recognition
The probe and meter automatically recognise the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic Temperature Compensation
Integrated temperature sensor allows for automatic temperature compensation of pH and conductivity measurements.
Read More
pH/mV Range | 0.00 to 14.00 pH/± 600.0 mV | |
Resolution | 0.01 pH/ 0.1 mV | |
Accuracy | ±0.02 pH/ ±0.5 mV | |
Calibration | automatic one, two or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer | |
ORP Range | ±2000.0 mV | |
ORP Resolution | 0.1 mV | |
ORP Accuracy | ±1.0 mV | |
ORP Calibration | automatic at one custom point (relative mV) | |
EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) | |
EC Resolution | Manual: 1μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; automatic: 1μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm | |
EC Accuracy | ±1% of reading or ± 1μS/cm whichever is greater | |
EC Calibration | automatic single point, with six standard solutions (84μS/cm, 1413μS/cm, 5.00mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point | |
TDS Range | 0 to 400.0 ppt (g/L) (the maximum value depends on the TDS factor) | |
TDS Resolution | manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 PPT(g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 pp (g/L) | |
TDS Accuracy | ±1% of reading or ±1 ppm (mg/L) whichever is greater | |
TDS Calibration | based on conductivity or salinity calibration | |
Resistivity Range | 0 to 999999 Ω.cm; 0 to 1000.0 kΩ.cm; 0 to 1.0000 MΩ.cm | |
Resistivity Resolution | dependent on resistivity reading | |
Resistivity Calibration | based on conductivity or salinity calibration | |
Salinity Range | 0.00 to 70.00 PSU | |
Salinity Resolution | 0.01 PSU | |
Salinity Accuracy | ±2% of reading or ±0.01 PSU whichever is greater | |
Salinity Calibration | based on conductivity calibration | |
Seawater σ Range | 0.0 to 50.0 σt, σ0, σ15 | |
Seawater σ Resolution | 0.1 σ t, σ0, σ 15 | |
Seawater σ Accuracy | ±1 σ t, σ0, σ 15 | |
Seawater σ Calibration | based on conductivity or salinity calibration | |
Temperature Range | -5.00 to 55.00°C | |
Temperature Resolution | 0.01°C | |
Temperature Accuracy | ±0.15°C | |
Temperature Calibration | Automatic at one custom point | |
Additional Specifications | ||
Temperature compensation | automatic from -5 to 55°C | |
Logging Memory | 45,000 records (continuous logging or log-on demand of all parameters | |
Logging Interval | one second to three hours | |
PC Connectivity | via USB (with Hanna PC software) | |
Environment | 0 to 50°C; RH 100% IP67 | |
Battery Type/Life | 1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight) | |
Dimensions/Weight | 185 x 93 x 35.2 mm/400g | |
Ordering information: | HI-981954 is supplied with HI-7698195 multiparameter probe with 4m cable, HI-7698194-1 pH/ORP sensor, HI-7698194-3 EC sensor, HI-9828-20 quick calibration solution, HI-76981952 probe maintenance kit, HI-76981943 calibration beaker, HI-9298194 Hanna PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom insert. |
Sensor inputs | two (pH or pH/ORP, EC) | |
Sample Environment | Fresh, brackish, seawater, pool and spa water | |
Waterproof Protection | IP68 | |
Operating temperature | -5 to 55°C | |
Storage Temperature | -20 to 70°C | |
Maximum Depth | 20 metres | |
Dimensions without cable | 342mm; 46mm diameter | |
Weight (without sensors) | 570g | |
Cable specification | Multistrand-multiconductor shielded cable with internal strength member rated for 68kg intermittent use | |
Wetted materials: | ||
Body | ABS | |
Threads | Nylon | |
Shield | ABS/316SS | |
Temperature probe | 316 SS | |
O-rings | EPD |