+44 (0)1525 850 855
Order before 4pm for same day dispatch Weekdays only
Menu
HI-763093 EC digital probe with 4m cable (for use with Hi-98199)

In Stock 1 Item available

HI-763093

When used with the HI-98199 this electrode allows for the measurement of conductivity, TDS (total dissolved solids), Resistivity, Salinity, seawater σ, and temperature.

EC

£371.60 (exc.VAT)
£445.92 (tax incl.)
Full Description Specification Manuals

When used with the HI-98199 Digital meter:

  • Single-point calibration from six standards
  • Temperature compensation Automatic Temperature Compensation
  • Configurable temperature coefficient range from 0.00 to 6.00%/°C
  • Choice of reference temperatures at 20 or 25°C
  • Absolute conductivity can be displayed along with the temperature compensated value

Auto-ranging

Salinity readings Practical Salinity Scale (PSU) based on conductivity calibration

Read More

EC
 Range0 to 200 mS/cm
 Resolutionmanual: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm
 Accuracy±1.5% of reading or ±2 μS/cm whichever is greater
 CalibrationAutomatic single point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS
  Range0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor)
 Resolutionmanual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L) automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L)
 Accuracy±1% of reading or ±1 ppm (mg/L) whichever is greater
 Calibrationbased on conductivity calibration
Resistivity
  Range0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
 Resolution1 Ω•cm; 0.1 kΩ•cm; 0.0001 MΩ•cm
 Calibrationbased on conductivity calibration
Salinity
  Range0.00 to 70.00 PSU
 Resolution0.01 PSU
 Accuracy±2% of reading or ±0.01 PSU whichever is greater
 Calibrationbased on conductivity calibration
Seawater σ
 Range0.0 to 50.0 σt, σ₀, σ₁₅
 Resolution0.1 σt, σ₀, σ₁₅
 Accuracy±1 σt, σ₀, σ₁₅
 Calibrationbased on conductivity calibration

Similar Products