HI-1006-3010 pH electrode with PTFE junction. High temperature glass bulb
HI-1006-3010
pH electrode with PTFE junction. High temperature glass bulb, BNC, 10M cable.
Hanna presents a series of combination pH electrodes incorporating over 20 years of electrode manufacturing experience.
The most advanced feature of this series is the electrode shape with a flat tip, virtually eliminating deposits that can foul the electrode, significantly reducing necessary maintenance. This characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.
- Self-cleaning flat tip sensor for significantly reduced maintenance
- Provided with an internal matching pin that can avoid typical problems caused by grounding loop current
- 3/4” NPT external thread on both ends for easy installation
Junction
Three junction types are available:
- Annular non-clogging PTFE junction, for testing solutions with high content of suspended solids or for high pressure installation
- Open junction, ideal for wastewater analysis
- Ceramic junction
Connection Type
- Electrodes are wired for direct connection to a transmitter or process controller, or with the standard BNC connector.
Glass Sensor
- Hanna has developed four types of specialised glass. First is a durable sensor glass for general purpose, industrial use. This glass can withstand the stress of daily use. The remaining types of electrode glass allow continuous monitoring in highly acidic solutions containing fluoride ions, as well as high or low temperature process and streams significantly increase the electrode life.
Built-in Amplifier
- Models with a built-in amplifier are necessary for long distance measurements, where it is not possible to install a transmitter. The internal amplifier can be powered directly from select Hanna process controllers or a power source that supplies the appropriate voltage.
Temperature Sensor
- The pH electrodes with built-in 3-wire Pt100 or Pt1000 temperature sensor allow for the temperature compensation of pH readings as well as temperature measurements.
Cable Length
- Non-amplified electrodes are provided with a 5, 10 or 15m cable, while the amplified models are provided with a 15, 25, 50 or 75m cable.
Select the flat tipped electrode that best fits your process requirements by choosing from the following technical characteristics listed in the specifications table.
Read More
HI-1006-4005 | ||
Cable Length | 5m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | Fluoride Resistant (HF) | |
Junction | PTFE | |
HI-1006-2405 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | Pt1000 | |
Glass type | General Purpose (GP) | |
Junction | PTFE | |
HI-1006-3005 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | High Temperature (HT) | |
Junction | PTFE | |
HI-1006-3007 | ||
Cable | 7m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | High Temperature (HT) | |
Junction | PTFE | |
HI-1006-3205 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | Pt100 | |
Glass Type | High Temperature (HT) | |
Junction | PTFE | |
HI-1006-2005 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | General purpose (GP) | |
Junction | PTFE | |
HI-1006-1005 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | Low Temperature (LT) | |
Junction | PTFE | |
HI-1006-3005 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | High Temperature (HT) | |
Junction | Ceramic | |
HI-1006-1007 | ||
Cable | 7m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | Low Temperature (LT) | |
Junction | PTFE | |
HI-1006-2010 | ||
Cable | 10m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | General Purpose (GP) | |
Junction | PTFE | |
HI-1006-2015 | ||
Cable | 15m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | General Purpose (GP) | |
Junction | PTFE | |
HI-1006-3010 | ||
Cable | 10m | |
Connection | BNC | |
Internal Temperature Sensor | No | |
Glass Type | High Temperature (HT) | |
Junction | PTFE | |
HI-1006-2210 | ||
Cable | 10m | |
Connection | BNC | |
Internal Temperature Sensor | Pt100 | |
Glass Type | General purpose (GP) | |
Junction | PTFE | |
HI-1006-1205 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | Pt100 | |
Glass Type | Low Temperature (LT) | |
Junction | PTFE | |
HI-1006-2205 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | Pt100 | |
Glass Type | General Purpose (GP) | |
Junction | PTFE | |
HI-1006-2305 | ||
Cable | 5m | |
Connection | Direct/colour-coded wires | |
Internal Temperature Sensor | Pt100 | |
Glass Type | General Purpose (GP) | |
Junction | PTFE | |
HI-1006-2505 | ||
Cable | 5m | |
Connection | Direct/colour-coded wires | |
Internal Temperature Sensor | Pt1000 | |
Glass Type | General Purpose (GP) | |
Junction | PTFE | |
HI-1006-4205 | ||
Cable | 5m | |
Connection | BNC | |
Internal Temperature Sensor | Pt100 | |
Glass Type | Fluoride Resistant (HF) | |
Junction | PTFE | |
HI-1006-2215 | ||
Cable | 15m | |
Connection | BNC | |
Internal Temperature Sensor | Pt100 | |
Glass Type | General Purpose (GP) | |
Junction | PTFE | |
HI-1006-3715 | ||
Cable | 15m | |
Connection | Direct/colour-coded wires | |
Internal Temperature Sensor | Pt100 | |
Glass Type | High Temperature (HT) | |
Junction | PTFE |