HI-122 Professional pH Bench Meter with Built-in Printer
HI-122-02
The Hanna HI-122 meter offer all the advanced capabilities for accurate pH measurement with the added feature of a built-in printer.
The Hanna HI-122-02 is a strong addition to the Hanna family of professional pH meters. This meter offers all the advanced capabilities for accurate pH measurement with the added feature of a built-in printer.
Along with sophisticated functions such as millesimal resolution and automatic temperature compensation, HI-122-02 is provided with our signature Calibration Check® system that evaluates the electrode condition and function in relation to calibration.
Together with the ability to customize a calibration curve with up to 5 points (selected from 7 stored plus 2 custom values), these products are suitable for any laboratory application. Such flexibility makes these meters ideal for both extreme acidic pH, and with very alkaline pH applications as well as precise pH neutral requirements.
The HI-122-02 adheres to Good Laboratory Practices and stores data and measurements for each calibration, with options to print directly or download to a PC through the RS232 port.
Order Information
The HI 122 is supplied with HI 1131P pH electrode, HI 7662-T temperature probe, pH 4 and pH 7 buffers, electrolyte solution, 5 paper rolls, 12 Vdc power adapter and instructions.
Read More
Range | pH | -2.00 to 16.00 pH; -2.000 to 16.000 pH |
Range | mV | ±999.9 mV; ±2000 mV |
Range | Temperature | -20.0 to 120.0°C |
Resolution | pH | 0.01 pH / 0.001 pH |
Resolution | mV | 0.1 mV / 1 mV |
Resolution | Temperature | 0.1°C |
Accuracy | pH | ±0.01 pH / ±0.002 pH |
Accuracy | mV | ±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV) / ±1 mV (±2000 mV) |
Accuracy | Temperature | ±0.4°C |
BNC Inputs | 1 for pH electrode | |
Calibration Check | Status of electrode condition and response time status of the buffer solutions during calibration | |
Relative mV Offset Range | ±2000 mV | |
pH Calibration | automatic, up to 5 points with 7 memorized values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers | |
Temperature Compensation | Automatic or manual, -20.0 to 120°C (-4 to 248°F) | |
pH Electrode | HI 1131P, glass body, refillable, BNC + pin connectors, 1 m cable (included) | |
Temperature Probe | HI 7662-T with 1 m (3.3') cable (included) | |
Input Impedance | 1012 | |
Log-On-Demand | 50 samples | |
Automatic Data Logging | 1000 samples | |
PC Connection | RS232 serial port, optoisolated | |
Printer | built-in, with 44 mm plain paper | |
Power Supply | 12 Vdc adapter (included) | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% | |
Dimensions | 280 x 203 x 84 mm (11.0 x 8.0 x 3.3") | |
Weight | 1.8 kg (4.0 lb.) |