BL-7917-2 ORP Controller and Pump
BL-7917-2
The BL7917 combines a ORP meter with a chemical dosing pump in order to maintain a desired set point in process applications.
- Two advanced instruments in one compact unit
- Convenient installation with all controls on front panel
- Widely used in plating, wastewater treatment, water treatment and swimming pools
- Isolated 4 to 20 mA recorder output
ORP
Full Description
Specification
Manuals
Print Page
Full Description
Specification
Manuals
- ORP controller and dosing pumps in one compact unit.
- ±5 mV accuracy with unbeatable performance.
- Isolated 4 to 20 mA recorder output.
- Proportional dosing slows the pump down when the measured ORP level approaches the set value which avoids over dosage of oxidising or reducing agents.
- Alarm contact is activated whenever the ORP reading varies more than 200 mV from the set point.
- Auxiliary contacts allow the user to attach a mixer or priming pump that is activated only when the pump is dosing.
- High Quality materials are used for all parts that come into contact with liquid.
Order Information:
The BL 7917 series is supplied with discharge and suction valves, polyethylene tubing, power cable and instructions.
Order Information:
The BL 7917 series is supplied with discharge and suction valves, polyethylene tubing, power cable and instructions.
Read More
Range | -999 mV to +999 mV | |
Resolution | 1 mV | |
Accuracy | mV | +5 mV |
Flow Rate | 13.3, 11.7, 10.1, 9.0, 7.8 (LPH) | |
Input Impedance | 1012 Ohm | |
Dosage | proportional, oxidizing or reducing, user selectable | |
Recorder Output | 4-20 mA (isolated) | |
Dosing Contact | 1 isolated contact, 2A, Max. 240V, resistive load, 1,000,000 strokes | |
Alarm Contact | 1 isolated contact, 2A, Max. 240V, resistive load, 1,000,000 strokes | |
Power Supply | See Chart | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
Dimensions | 181 x 221 x 142 mm (7.1 x 8.7 x 5.6") | |
Weight | 5 kg (11 lb.) |