+44 (0)1525 850 855
Order before 4pm for same day dispatch Weekdays only
Menu

BL-982411-0

BL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces.

ORP

£233.50 (exc.VAT)
£280.20 (tax incl.)
Order now for 2 weeks delivery
Full Description Specification Manuals

BL 982411 is an ORP mini controller for panel mounting, specially designed for swimming pools and spas. Thanks to its compact size, BL 982411 can be installed in small spaces. BL 982411 is the ideal solution for those who have always checked ORP manually. Thanks to the automatic dosing, this mini controller will significantly reduce maintenance time.

BL 982411 can be used with any ORP electrode with standard BNC connector. The instrument measures ORP in the 0 to 1000 mV range and shows the readings on the large display.

The status LED continuously indicates if the controller is in measurement, dosing or alarm mode.

BL 982411 is also provided with a relay for selecting the dosing direction, oxidizing or reducing.

You can also choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits you to enable or disable the dosing relay according to your need.

The overtime control system advises you when the relay is active for too long, helping to prevent over-dosage.

Order Information:
The BL 982411 is supplied with mounting brackets, transparent cover, and instructions.

Resolution   1 mV
Accuracy   ±5 mV
Calibration   manual, with CAL trimmer
Dosing Relay   1, max 2A (fuse protected), 250 Vac, 30 Vdc
Dosing Selection   reducing or oxidizing
contact open = reducing dosage, activated when reading exceeds setpoint value
contact closed = oxidizing dosage; activated when reading falls below setpoint value
Setpoint   adjustable from 0 to 1000 mV
Overtime   adjustable, typically from 5 to approx. 30 minutes
Input Impedance   102 Ohm
Power Supply   See Chart
Dimensions   83 x 53 x 99 mm (3.3 x 2.1 x 3.9")
Weight   See Chart

Read More

Range0 to 1000 mV
Resolution1 mV
Accuracy±5 mV
Calibrationmanual, with CAL trimmer
Dosing Relay1, max 2A (fuse protected), 250 Vac, 30 Vdc
Dosing Selectionreducing or oxidizing
contact open = reducing dosage, activated when reading exceeds setpoint value
contact closed = oxidizing dosage; activated when reading falls below setpoint value
Setpointadjustable from 0 to 1000 mV
Overtimeadjustable, typically from 5 to approx. 30 minutes
Input Impedance102 Ohm
Power Supply230v
Dimensions83 x 53 x 99 mm (3.3 x 2.1 x 3.9")