+44 (0)1525 850 855
Order before 4pm for same day dispatch Weekdays only
Menu
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester
Hanna Instruments UK AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester

AGRIKIT

The AGRIKIT contains all you need to grow successful fruit and vegetables from soil preparation and analysis to sugar content in the final crop. Also included in the kit are cleaning and storage solutions for the Groline combo tester.

£685.00 (exc.VAT)
£822.00 (tax incl.)
Order now for 2 weeks delivery
Accessories
Reference
Price
Quantity
Full Description Specification Manuals

AGRIKIT - Agricultural kit featuring HI-98131 Groline pH/EC/TDS combo tester

Agricultural kit comprising:

  • HI-98131 - Groline pH/EC/TDS combo tester
  • HI-96801 - refractometer
  • HI-70300M - storage solution
  • HI-740036P - 1 x Beaker
  • HI-7061M - cleaning solution
  • HI-large grey case

About the equipment included:

The HI-98131 is a slim, lightweight, and waterproof pocket tester that measures pH, conductivity, TDS and temperature. This versatile pocket meter is designed for hydroponics, greenhouse and agriculture applications.

The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI-98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).

The HI-98131 GroLine tester features a large multi level LCD which displays both pH, EC or TDS and temperature readings simultaneously. The pH readings are displayed with a 0.01 resolution, while the EC and TDS readings are displayed with a 0.01 mS/cm and 10 ppm (mg/L) resolution.

An exposed temperature sensor allows for rapid temperature compensated measurements of EC and TDS. The LCD screen has indicators for calibration status and stability. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

The HI-96801 is used across the food industry for measuring the concentrations of general purpose sugars in foods.

Quick and easy to use it is ideal for analysing the sugar content in a wide range of food products including fruit, energy drinks, puddings, tofu, jams, honey, soups and sauces.

Priced to ensure tougher economic times do not have to mean a compromise on accuracy, the Hanna refractometer offers all the benefits of high precision digital technology at the same price as a mechanical model.

The HI-96801 measures the refractive index to determine the % Brix of sugar in aqueous solutions. The refractive index of the sample is then converted to % Brix concentration units.

Product uses

  • Fruit growers and importers
  • Fruit juice & drink manufacturers
  • Production of jams, preserves & sauces

HI-7061M is a general purpose cleaning solution which can be used for a variety of applications. Electrodes become dirty from use and will produce inaccurate results even if they read correctly in a pH buffer. HANNA’s cleaning solutions eliminate impurities and residues which are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. You can also choose from our specialist list of cleaning solutions for one more suitable for your needs (purchased separately).

HI-70300M is a storage solution prepared with reagent grade chemicals which can be used to ensure maximum performance of your pH and ORP electrodes.

After cleaning your electrode with one of our wide range of cleaning solutions, rinse with tap water, then soak the electrode in Hanna specially formulated Storage Solution (HI-70300 or HI-80300) before taking measurements. pH 4.01 or pH7.01 buffer solution can be used if Storage Solution is running low.

Between measurements, storage solutions minimise microbial growth and prevent any effects of diffusion and Osmosis, as well as keeping the sensor tip and reference junction hydrated and clear – all important for an optimum response time and measurement.

Air-tight bottles with tamper-proof seals ensure quality and freshness of storage solution. Each bottle is marked with a batch number and expiry date.

HI-7061M is a general purpose cleaning solution which can be used for a variety of applications. Electrodes become dirty from use and will produce inaccurate results even if they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues which are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly.

One HI-740036 is 100mL plastic beaker is supplied.

All the products are transportable in a large grey carrying case.

Read More

HI-98131 Groline pH/EC/TDS combo tester
RangepH 0.00 to 14.00 pH
Conductivity 0.00 to 6.00 mS/cm
TDS 0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF)
Temperature 0.0 to 60.0°C
Resolution0.01 pH
Conductivity 0.01 mS/cm
TDS 10 ppm (mg/L)
Temperature 0.1°C
AccuracypH ±0.1 pH
Conductivity ±2% F.S.
TDS ±2% F.S.
Temperature ±0.5°C
pH Calibrationautomatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution
Temperature CompensationpH: automatic; EC/TDS: automatic with β set at 1.9%/°C
Battery Type / Life1.5V (4) / approx. 100 hours of continuous use, auto-off after 8 minutes of non-use
Environment-5 to 50°C; RH max 100%
Dimensions163 x 40 x 26 mm
Weight100 g (3.5 oz.)
Ordering InformationHI-98131 is supplied with HI-73127 pH electrode, HI-73128 electrode removal tool, batteries (4), instructions and quality certificate.
HI-96801 Refractometer
Range0 to 85% Brix / 0 to 80°C (32 to 176°F)
Resolution± 0.1% Brix / ±0.1°C (±0.1°F)
Accuracy± 0.2 % Brix / ± 0.3°C (±0.5°F)
Automatic Temperature Compensationbetween 10 and 40°C (50 - 104°F)
Measurement TimeApproximately 1.5 seconds
Minimum Sample Volume2 metric drops
Light SourceYellow LED
Sample CellStainless steel ring and flint glass prism
Case MaterialABS
Enclosure RatingIP65
Battery Type / Life(1) 9V / 5000 readings
Auto-OffAfter 3 minutes of non-use
Dimensions19.2(W) x 10.2(D) x 6.7 (H)cm
Weight420g
HI-70300M Electrode storage solution
DescriptionElectrode Storage Solution
PackageBottles
Size230ml
Quantity1
Certificate of AnalysisNo

HI-7061M Cleaning Solution
Size230ml
Quantity1
Certificate of AnalysisNo

Similar Products