Hanna Instruments

Scientific Equipment

HI-93731-01 Zinc Reagent, Zincon Method

HI-93731-01 Zinc Reagent, Zincon Method

HI-93731-01 Zinc Reagent, Zincon Method

HI-93731-01 Zinc Reagent, Zincon Method

100 tests
Range: 0.00 to 3.00 mg/L
In Stock
£52.50 (exc. VAT) £63.00 (inc. VAT)

The HI-93731-01 are reagents for the colorimetric determination of zinc. There are enough reagents for 100 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each bottle and packet for traceability.

Zinc reagent for use with the Hanna HI-96731, HI-83300, HI-83305, HI-83306, HI-83308 and HI-83099 photometers.

Reagents are supplied in individual sachets containing fast dissolving powder.

HI-93731-01 Zinc Reagent, Zincon Method information

Hanna's extended description

The HI-93731-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Zincon method. The reaction between zinc and the reagents causes a brownish-green to a blue tint in the sample. By simply adding the reagents to the sample, a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration. The results will be displayed in mg/L (ppm) of zinc. These reagents are designed to be used with samples that have an expected range of 0.00 to 3.00 mg/L zinc.

Tip for an accurate measurement

It is important that the sample does not contain any debris.

When the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.

Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.

Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.

After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.

Specifications

Specifications list

Specifications

Package Dropper bottle and packet
Quantity 100 tests
Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Zincon method. The reaction between zinc and the reagent causes a brownish-green to a blue tint in the sample.

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.