Responding to the user's requirements for analysing high concentrations of chlorine, Hanna offers the HI 96734, that permits free and total chlorine analysis up to 10.00 mg/mL.

HI-96734C Free and Total Chlorine Photometer Kit, High Range information

Hanna's extended description

All instruments are factory calibrated and the electronic and optical design minimises the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. HI-96734 utilises an adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl. The reaction between free and total chlorine and DPD reagent causes a pink tint in the sample.

This auto-diagnostic portable photometer is dedicated to monitoring over-chlorination through to chlorinamine destruction. The advanced optical system employs a specialised tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvettes are constructed from specialised optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvette is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvette with a wide neck to make it easier to add both sample and reagents.

Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.

Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Specifications

Specifications list

Specifications

Parameter Chlorine, Free and Total High Range
Range Free Cl²: 0.00 to 10.00 mg/L; Total Cl²: 0.00 to 10.00 mg/L
Accuracy ±0.06 mg/L @ 3.00 mg/L
Filter Narrow band @ 525 nm
Method Adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample.
Environment 0 to 50°C (32 to 122°F); Max 95% RH non-condensing
Battery Type / Life (1) 9V/approx. 200 hours continuous use
Auto Shut-off After 10 min. of non-use in measurement mode
Dimensions 192 x 102 x 67 mm (7.6 x 4 x 2.6")
Weight 290 g (10 oz.)

Downloadable Manuals

Manuals

Download PDF

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.