HI-96715 Ammonia Photometer, medium range with Cal Check®

HI-96715 Ammonia Photometer, medium range with Cal Check®

HANNA HI-96715 MR Ammonia Photometer with Cal Check®

HI-96715 Ammonia Photometer, medium range with Cal Check®

Complete with cuvettes
2 year manufacturer warranty
In Stock
£428.10 (exc. VAT) £513.72 (inc. VAT)

Portable photometers are for the measurement of ammonia nitrogen in fresh or salt water samples.

HI-96715 Ammonia Photometer, medium range with Cal Check® information

Hanna's extended description

Designed to measure the ammonia-nitrogen content in water samples, the HI-96715 is ideal for use in a wide range of applications.

Offering high levels of accuracy as well as being water resistant, portable and easy to use, this meter is hugely popular with operators across the water industry.

A measurement range of 0.00 to 9.99 ppm makes it the optimum solution for quick, efficient and economical ammonia measurement.

Present naturally in surface and wastewaters, ammonia mainly results from the deamination of organic nitrogen-containing compounds and hydrolysis of urea. Ammonia may also be present from water treatment processes that utilise chloramines for disinfection, where ammonia is added to the water to react with chlorine. Ammonia is less likely to appear in groundwater due to absorption to soil particles.

Ideal for

  • Water: fresh and salt water fish tanks and farms, lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water
  • Key features


      • CAL Check - Allows for performance verification and calibration of the meter using NIST traceable standards
      • GLP – Review of the last calibration date
      • Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on
      • Battery status indicator – Indicates the amount of battery life left
      • Built-in timer – Display of time remaining before a measurement is taken. Ensures that all reading are taken at the appropriate reaction intervals for the test being performed
      • Error message – Messages on display alerting to problems including no cap, high zero, and standard too low
      • Cooling lamp indicator – To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken
      • Units of measurement – Appropriate unit of measure is displayed along with reading

      Designed for precision

      With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

      All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.

      Supplied with
    • 2 glass cuvettes
    • 9V battery
    • NB: reagents ordered separately


    Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.



    Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.

    Specifications

    Specifications list

    Specifications

    Parameter Ammonia, Medium Range
    Range 0.00 to 9.99 mg/L (as NH³-N)
    Accuracy ±0.12 mg/L @ 6.00 mg/L
    Filter Narrow band @ 466 nm
    Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler Method. The reaction between ammonia and the reagents causes a yellow tint in the sample.
    Light Source Tungsten lamp; LED
    Environment 0 to 50°C (32 to 122°F); Max 95% RH non-condensing
    Battery Type / Life (1) 9V/approx. 200 hours continuous use
    Auto Shut-off After 10 min. of non-use in measurement mode
    Dimensions 192 x 102 x 67 mm (7.6 x 4 x 2.6")
    Weight 290 g (10 oz.)
    Reagents and Standards HI-96715-11 CAL Check standard cuvettes; HI-93715-01 Reagents for 100 tests N-NH3 MR; HI-93715-03 Reagents for 300 tests N-NH3 MR
    INTERFERENCE
     Interference may be caused by: Acetone
    Alcohols
    Aldehydes
    Glycine
    Hardness above 1 g/L
    Iron
    Organic chloramines
    Sulphide
    Various aliphatic and aromatic amines