+44 (0)1525 850 855
Order before 4pm for same day dispatch Weekdays only
Menu
HANNA HI-98197 Professional Waterproof Meter for Ultrapure Water
HANNA HI-98197 Professional Waterproof Meter for Ultrapure Water

In Stock 2 Items available

HI-98197

The HI-98197 is a waterproof, portable EC (conductivity) meter that has an expanded conductivity range from 0.000 µS/cm to 400 mS/cm, as well as TDS (Total Dissolved Solids), resistivity, and three salinity scales.

Salinity
Resistivity
Conductivity & TDS

£1,805.10 (exc.VAT)
£2,166.12 (tax incl.)
Accessories
Reference
Price
Quantity
Full Description Specification Manuals

HI-98197 Professional Waterproof Meter for Ultrapure Water

This meter offers a quick connect four-ring probe and allows the user to adjust the nominal cell constant, HI-98197 is also ready to perform all three stages of USP <645> method required for EC measurement of water for injection.

Key features:

  • Conductivity and resistivity – high resolution of 0.001µS/cm for conductivity and 0.1 MΩ•cm for resistivity
  • Calibration – Perform up to a five point calibration for enhanced accuracy
  • Temperature Compensation – Automatic Temperature Compensation & configurable temperature coefficient range from 0.00 to 10.00%/°C
  • Approximately 100 hour battery life – powered by (4) 1.5V AA Batteries
  • Four-ring platinum probe – this probe can cover low EC samples to 1000 mS/cm (actual EC) - HI-763123
  • Waterproof – IP67 rated waterproof, rugged enclosure
  • Clear display – Graphic LCD display with multi-function virtual keys
  • Autohold – automatically holds the first stable reading on the display

  • Enhanced calibration – An “out of calibration range” warning blinks if the measurement range is not covered by the current calibration
  • Calibration timeout – Alerts when calibration is due at a specified interval
  • Connectivity – PC connectivity via opto-isolated micro-USB with HI-92000 software
  • Data logging – The HI-98197 allows storage of up to 400 log-on demand samples or 1000 lot logging samples that can be later transferred to a PC with the supplied USB cable and software
  • GLP – GLP data provides information from previous calibration to ensure good laboratory practices are met
  • Intuitive keypad – Most of the available options such as GLP information, help, range, calibration, and backlight have a dedicated button
  • HI-605453 Stainless steel flow cell for ultrapure water
  • Supplied complete with sensor, flow cell, tubing, calibration solution, beakers, PC software and connection cable, instruction manual, quick start guide and batteries in the HI-720197 rugged, custom carrying case.

Designed for water professionals

High purity water used in power generation, semi-conductor manufacturing, and other industries can be difficult to measure due to the ability of carbon dioxide (CO2) to diffuse into water and form carbonic acid (H2CO3).

Carbonic acid quickly dissociates into hydrogen ions (H+) and bicarbonate ions (HCO-3). These ions will increase the conductivity and decrease the resistivity of the water. In order to measure high purity water accurately, it is necessary to perform a continuous flow measurement.

HI-98197 uses the HI-763123 four-ring probe with a threaded connection that is screwed into a stainless steel body flow cell. The flow cell is then connected to a water source to more accurately determine the conductivity or resistivity without exposure to air. Hi-98197 is an ideal meter for monitoring the efficiency of a mixed bed resin or equivalent system that produces high purity water of 18.2 MΩ•cm at 25°C.

Backlit Graphic LCD Display

The HI-98197 features a backlit graphic LCD with on-screen help. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.

Quick connect probe

The HI-763123 four-ring platinum conductivity probe with a threaded connection features a quick connect DIN connector to make attaching and removing the probe simple and easy.

Waterproof protection

The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1m for up to 30 minutes.

Calibration

Choose from seven memorised standards and obtain up to a five point conductivity calibration. For salinity (% range), HI-7037 standard allows users to perform a one point calibration.

Measurement

EC and TDS measurements are fully customisable and include: cell constant selection between 0.010 and 10.000, selection of linear or natural water (non-linear) or no temperature compensation (for actual conductivity reading), configurable temperature compensation coefficient range from 0.00 to 10.00%/°C, choice of reference temperatures of 15°C, 20°C and 25°C, and a selectable TDS factor between 0.40 and 1.00.

Ten sets of customised measurement parameters can be stored as a user profile and later recalled.

Autohold

Pressing Autohold during measurement will automatically hold the first stable reading on the display.

USP <645>

HI-98197 can be used to perform all three stages of USP <645> method required for EC measurement of water for injection and generates a report when any of the three stages are met. An on-screen guide instructs on each USP stage. A progress bar displays reading stability progress towards meeting stage 2 requirements.

Data logging

The HI-98197s allow storage of up to 400 log-on demand samples or 1000 lot logging samples that can be later transferred to a PC with the supplied HI-920015 USB cable and HI-92000 software.

GLP

Comprehensive GLP functions are directly accessible by pressing the GLP Key. Calibration data, including date, time and calibration values are stored for retrieval at a later time.

Intuitive keypad

The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.

Dedicated help key

Contextual help is always available through a dedicated HELP key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.

Setup screen

Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.

PC Connectivity

Logged data can be transferred to a Windows compatible PC with the included HI-920015 micro USB cable and HI-92000 software.

Long Battery Life

The display of the meter has a battery icon indicator to show the remaining power. The meter uses four 1.5V AA batteries that provide up to 200 hours of battery life.

Read More

EC Range0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibrationautomatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
TDS Calibrationbased on conductivity calibration
Resistivity Range1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
Resistivity Accuracy±1% of reading (±10 Ω or 1 digit, whichever is greater)
Resistivity Calibrationbased on conductivity calibration
Salinity Range% NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale - UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution0.1%; 0.01
Salinity Accuracy±1% of reading
Salinity Calibrationmax. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges
Temperature Range-20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution0.1°C (0.1°F)
Temperature Accuracy±0.2°C; ±0.4°F (excluding probe error)
Temperature Calibrationone or two points
Temperature CompensationnoTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Measurement Modesautorange, autoend, lock and fixed range
Reference Temperature15°C, 20°C and 25°C
Temperature Coefficient0.00 to 10.00 %/°C
TDS Factor0.40 to 1.00
Electrode/ProbeHI-763123 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m cable (included)
Log-on-demand400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorised Profilesup to 10
PC Connectivityopto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-offuser selectable: 5, 10, 30, 60 min or can be disabled
Environment0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight400 g (14.2 oz.)
Ordering InformationHI-98197 is supplied with HI-763123 conductivity probe, HI-605453 stainless steel flow cell, HI-7033M 84 μS/cm calibration solution (230 mL), HI-7031M 1413 μS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI-92000 PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instructions and rugged carrying case.
Warranty2 years (probe 6 months)

Similar Products