+44 (0)1525 850 855
Order before 4pm for same day dispatch Weekdays only
Menu
Hanna HI-83414-02 Turbidity and Free and Total Chlorine Meter

In Stock 1 Item available

HI-83414-02

The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.

2 year manufacturers' warranty

£2,431.30 (exc.VAT)
£2,917.56 (tax incl.)
Full Description Specification

HI-83414-02 Turbidity and Free and Total Chlorine Meter

The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.

The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp.

The colorimeter portion of the meter uses a 525nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine. All measurements are performed with 25mm round cuvettes composed of special optical glass to ensure maximum repeatability of turbidity and chlorine measurements.

More benefits:

  • EPA Compliant
  • Backlit Graphic LCD
  • Light blocking cuvette cover
  • Four measurement modes
  • Multiple turbidity units of measure
  • Multiple reading modes
  • Calibration - 2, 3, 4 or five-point turbidity calibration, plus warning messages
  • CAL Check™
  • Out of Cal Range function
  • GLP data
  • Data logging
  • Data Transfer
  • Tutorial mode
  • Contextual help

Read More

Turbidity Range – non-ratio mode0.00 to 9.99 NTU
10.0 to 40.0 NTU
0.0 to 99.9 NTU
100 to 268 Nephelos
0.0 to 9.80 EBC
Turbidity resolution – non-ratio mode0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC
Turbidity Range – ratio mode0.00 to 9.99 NTU
10.0 to 99.9 NTU
100 to 4000 NTU
0.0 to 99.9 NTU
100 to 26800 Nephelos
0.00 to 9.99 NTU
10.0 to 99.9
100 to 980 EBC
Turbidity resolution – ratio mode0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC
Free and Total Chlorine Range0.00 to 5.00 mg/L
Range SelectionAutomatic
Free and Total Chlorine Resolution0.01 mg/L from 0.00 to 3.50mg/L
0.10 above 3.50 mg/L
Turbidity Accuracy±2% of reading plus 0.02 NTU; ±5% of reading above 1000 NTU
Free and Total Chlorine Accuracy±0.02 mg/L @ 1.00 mg/L
Repeatability±1% of reading or 0.02 NTU, whichever is greater
Stray Light< 0.02 NTU
Light Sourcetungsten filament lamp
Light DetectorSilicon Photocell
Turbidity MethodRatio Nephelometric Method (90° and 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Free and Total Chlorine MethodAdaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G
Turbidity Standards< 0.1, 15, 100, 750 & 2000 NTU
Free and Total Chlorine Standards1.00 mg/L free chlorine, 1.00 mg/L total chlorine
Turbidity CalibrationTwo, three, four or five point calibration
Free and Total Chlorine Calibrationone-point calibration
Logging Memory200 records
Serial InterfaceUSB
Environmentup to 50°C (32 to 122°F); max 95% RH non-condensing
Power Supply230 Vac adapter
Auto Shut-offAfter 15 minutes of non-use
Dimensions230 x 200 x 145 mm
Weight2.5kg
Order InformationHI-83414-02 is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity (HI-88703-11) and colorimeter (HI-93414-11), silicone oil (HI-98703-58), cuvette wiping cloth, scissors, power cord and instruction manual.