HI-83414-02 Turbidity and Free and Total Chlorine Meter
In Stock 1 Item available
HI-83414-02
The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.
HI-83414-02 Turbidity and Free and Total Chlorine Meter
The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.
The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp.
The colorimeter portion of the meter uses a 525nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine. All measurements are performed with 25mm round cuvettes composed of special optical glass to ensure maximum repeatability of turbidity and chlorine measurements.
More benefits:
- EPA Compliant
- Backlit Graphic LCD
- Light blocking cuvette cover
- Four measurement modes
- Multiple turbidity units of measure
- Multiple reading modes
- Calibration - 2, 3, 4 or five-point turbidity calibration, plus warning messages
- CAL Check™
- Out of Cal Range function
- GLP data
- Data logging
- Data Transfer
- Tutorial mode
- Contextual help
Read More
Turbidity Range – non-ratio mode | 0.00 to 9.99 NTU 10.0 to 40.0 NTU 0.0 to 99.9 NTU 100 to 268 Nephelos 0.0 to 9.80 EBC | |
Turbidity resolution – non-ratio mode | 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC | |
Turbidity Range – ratio mode | 0.00 to 9.99 NTU 10.0 to 99.9 NTU 100 to 4000 NTU 0.0 to 99.9 NTU 100 to 26800 Nephelos 0.00 to 9.99 NTU 10.0 to 99.9 100 to 980 EBC | |
Turbidity resolution – ratio mode | 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC | |
Free and Total Chlorine Range | 0.00 to 5.00 mg/L | |
Range Selection | Automatic | |
Free and Total Chlorine Resolution | 0.01 mg/L from 0.00 to 3.50mg/L 0.10 above 3.50 mg/L | |
Turbidity Accuracy | ±2% of reading plus 0.02 NTU; ±5% of reading above 1000 NTU | |
Free and Total Chlorine Accuracy | ±0.02 mg/L @ 1.00 mg/L | |
Repeatability | ±1% of reading or 0.02 NTU, whichever is greater | |
Stray Light | < 0.02 NTU | |
Light Source | tungsten filament lamp | |
Light Detector | Silicon Photocell | |
Turbidity Method | Ratio Nephelometric Method (90° and 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B | |
Free and Total Chlorine Method | Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G | |
Turbidity Standards | < 0.1, 15, 100, 750 & 2000 NTU | |
Free and Total Chlorine Standards | 1.00 mg/L free chlorine, 1.00 mg/L total chlorine | |
Turbidity Calibration | Two, three, four or five point calibration | |
Free and Total Chlorine Calibration | one-point calibration | |
Logging Memory | 200 records | |
Serial Interface | USB | |
Environment | up to 50°C (32 to 122°F); max 95% RH non-condensing | |
Power Supply | 230 Vac adapter | |
Auto Shut-off | After 15 minutes of non-use | |
Dimensions | 230 x 200 x 145 mm | |
Weight | 2.5kg | |
Order Information | HI-83414-02 is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity (HI-88703-11) and colorimeter (HI-93414-11), silicone oil (HI-98703-58), cuvette wiping cloth, scissors, power cord and instruction manual. |