Hanna Instruments

Scientific Equipment

HI-7609829-4 Spare EC &TURBIDITY sensor for HI-7609829/HI-7629829 series of probes

HI-7609829-4 Spare EC &TURBIDITY sensor for HI-7609829/HI-7629829 series of probes

HI-7609829-4 Spare EC &TURBIDITY sensor for HI-7609829/HI-7629829 series of probes

Temp range: -5 to 55°C
Size: 135 x 35mm
£757.55 (exc. VAT) £909.06 (inc. VAT)

The HI-7609829-4 is a combined conductivity and turbidity sensor for use with Hanna’s HI-9829 Multi-parameter Portable Meter. The sensor body is made from durable ABS and epoxy material. The 4-ring conductivity sensor contains AISI 316 stainless steel electrodes.

Sensor can be used with the HI-7609829 & HI-7629829 series of probes.

HI-7609829-4 Spare EC &TURBIDITY sensor for HI-7609829/HI-7629829 series of probes information

Hanna's extended description

Conductivity/Turbidity sensor


EC/Turbidity sensor, with o-ring, to be used with HI-9829 and HI-98290 multi-parameter meters.


By design, turbidity measurements conform to ISO 7027 standards using an optical technique to measure suspended particles in water.

The HI-7609829-4 is a combined conductivity and turbidity sensor for use with Hanna’s HI-9829 Multiparameter Portable Meter. The sensor body is constructed of durable ABS and epoxy material. The 4 ring conductivity sensor contains AISI 316 stainless steel electrodes that are not subject to polarisation or surface coating effects. By design, turbidity measurements conform to ISO 7027 standards using an optical technique to measure suspended particles in water.

Turbidity is the amount of particulate matter that is suspended in water. Turbidity measures the scattering effect that suspended solids have on light; the higher the intensity of scattered light, the higher the turbidity. Material that causes water to be turbid include: clay, silt, finely divided organic and inorganic matter, soluble coloured organic compounds, plankton and microscopic organisms. Conductivity measurement is the same as in the HI-7609829-3.



IP68 - Dust-tight and protected against the effects of continuous immersion in water beyond 1m.

Specifications

Specifications list

Specifications

Sensor HI-7609829-4
Description EC/Turbidity Sensor
Measurement Type FTU, EC
Measurement Range 0.0 to 200.0 mS/cm; 0.0 to 400 mS/cm (absolute); 0.0 to 1000 FNU
Temperature Range -5 to 55 °C
Body ABS/epoxy, PMMA
Dimensions 135 x 35 mm
Depth 20 metres (65 feet)

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.