Hanna Instruments

Scientific Equipment

HI-93737-01 Silver Reagents, Pan Method

HI-93737-01 Silver Reagents, Pan Method

Hanna HI-93737-01 Silver Reagents, Pan Method

HI-93737-01 Silver Reagents, Pan Method

50 tests
Range: 0.000 to 1.000 mg/L
In Stock
£176.00 (exc. VAT) £211.20 (inc. VAT)

The HI-93737-01 are reagents for the colorimetric determination of silver. There are enough reagents for 50 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each bottle for traceability. For use with the Hanna HI-93737, HI-83200, HI-83206, HI-83206, HI-83208, HI-83099 & HI-833 series photometers.

HI-93737-01 Silver Reagents, Pan Method information

Hanna's extended description

The HI-93737-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the 1-(2-pyridylazo)-2-naphthol (PAN) method. The reaction between silver and the reagents causes an orange tint in the sample. By simply adding the reagents to the sample, a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the colour that is produced. The results will be displayed in mg/L (ppm) of silver. These reagents are designed to be used with samples that have an expected range of 0.000 to 1.000 mg/L silver.

Tip for an accurate measurement

It is important that the sample does not contain any debris.

When the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.

Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.

Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.

After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.

Specifications

Specifications list

Specifications

Package Packets
Quantity 50 tests
Method Adaptation of the 1-(2-pyridylazo)-2-naphthol (PAN) method. The reaction between silver and reagents causes an orange tint in the sample.