HI-96750 Potassium Portable Photometer

HI-96750 Potassium Portable Photometer

HI-96750 Potassium Portable Photometer

HI-96750 Potassium Portable Photometer

Complete with cuvettes
2 year manufacturer warranty
£279.45 (exc. VAT) £335.34 (inc. VAT)

The HI-96750 measures the potassium (K) content in water samples in the 0.0 to 10.0 mg/L (ppm) for low range and 10 to 100 mg/L (ppm) for medium range. Supplied with 2 cuvettes and caps.

Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.
Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Frequently Bought Together

Price for all:
£403.15

HI-96750 Potassium Portable Photometer information

Hanna's extended description

Potassium Portable Photometer

The HI-96750 uses the Tetraphenylborate Method. The reaction between potassium and reagents causes turbidity in the sample.

Potassium as a chemical element is commonly found in nature. It is present in soil and drinking water and is also an essential element for the growth of plants and animals.

Potassium concentration is important in determining the quality of soil in many greenhouse, agriculture and horticulture applications. Potassium salts are also a common component of fertilisers.


Key features

  • Clear display messages make the instrument quick and easy to operate
  • The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button
  • Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell
  • Auto shut off feature turns meter off after 10 minutes of non-use to save battery life
  • Fully water resistant
  • Clear easy to use function buttons
  • Direct readout of parameter measured

Designed for precision

With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.


Order information

  • Meter only (HI -96750): 2 glass cuvettes, 9V battery

NB: reagents ordered separately



Specifications

Specifications list

Specifications

Range LR: 0.00 to 10.0 mg/L (ppm); MR: 10 to 100 mg/L (ppm)
Resolution LR: 0.01 mg/L; MR: 1 mg/L
Accuracy LR: ±1.5 mg/L ±7% of reading; MR ±15 mg/L ±7% of reading
Light Source LED
Light Detection Silicon Photocell with narrow band interference filter @ 466nm
Battery Type / Life 1 x 9V / approx.
auto-off after 10 minutes of non use
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 193 x 104 x 69 mm
Weight 360 g
Method Adaptation of the Turbidimetric Tetraphenylborate Method.
Ordering Information HI-96750 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.
Reagents and Standards (sold separately) HI-96750-11 CAL CheckTM standard cuvettes; HI-93750-01 Reagent for 100 tests; HI-93750-03 Reagents for 300 tests
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
Interference may be caused by: The following ions do not interfere below these concentrations: Ammonium 10ppm, Calcium 10000ppm as CaCO3, Chloride 12000ppm, Magnesium 8000ppm as CaCO3, Sodium 8000ppm. Colour or suspended matter in large amounts will cause interference.

Questions & Answers