HI-93710-01 pH Reagent, Phenol Red Method, 100 tests

HI-93710-01 pH Reagent, Phenol Red Method, 100 tests

HANNA HI-93710-01 pH Reagent, Phenol Red Method

HI-93710-01 pH Reagent, Phenol Red Method, 100 tests

100 tests
Range: 6.5 to 8.5 pH
In Stock
£21.90 (exc. VAT) £26.28 (inc. VAT)

The HI-93710-01 are reagents for the colorimetric determination of pH. There are enough reagents for 100 tests to be used with Hanna’s compatible benchtop and portable photometers. These high quality reagents are clearly marked with the lot number and expiry date on each bottle for traceability.

HI-93710-01 pH Reagent, Phenol Red Method, 100 tests information

Hanna's extended description

The HI-93710-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Phenol Red method in which the reagents produce a range of colour that is pH-dependent. By simply adding 5 drops from the bottle of reagent to the sample, the reaction between the sample and reagent causes a tint in the sample that varies from yellow to red. The intensity of colour is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in pH units with a resolution of 0.1 pH. These reagents are designed to be used with samples that have an expected range of 6.5 to 8.5 pH.

Tip for an accurate measurement

It is important that the sample does not contain any debris.

When the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.

Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.

Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.

After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.

Specifications

Specifications list

Specifications

Package Dropper bottle
Quantity 100 tests
Method Phenol red method
Website easy to use and place an order

Good product, gives accurate results using an aqua ion meter. - by Trusted Customer