HI-141GH Datalogger with Internal & External Sensor and LCD

HI-141GH Datalogger with Internal & External Sensor and LCD

Hanna HI-141GH Datalogger with Internal & External Sensor and LCD

HI-141GH Datalogger with Internal & External Sensor and LCD

Internal & External sensor
2 year manufacturer warranty
In Stock
£274.90 (exc. VAT) £329.88 (inc. VAT)

The HI-141 dataloggers represent the most economical and secure way of monitoring temperature continuously over long periods of time. The models are housed in a rugged, waterproof ABS casing sealed against dust and water. The HI-141 series offers the choice of one or two channels, internal or external temperature sensors, and an optional LCD.

HI-141GH Datalogger with Internal & External Sensor and LCD information

Hanna's extended description

The HI-141 dataloggers can be placed with goods on the move, on supermarket shelves and in warehouses. They record the temperature at a given interval to make sure that perishable goods are not left unattended. The dataloggers can provide extra guarantee that goods never ventured out of limits of public safety.

HI-141 models offer users many alternatives, including one or two channels, internal or external temperature sensors, and an optional LCD display.

External temperature sensor models feature one or two stainless steel sensors on a 1 m (3.3’) cable for direct insertion.

HI-141 can store up to 16,000 temperature samples in a protected, non-volatile EEPROM memory. The logging interval can be set from once per second to once per 24 hour period, and logging delay can be set anywhere up to 199 hours. The MIN or MAX temperature between logging intervals can also be stored.

All of your collected data is tamper-proof and stored into serial numbered lots. All parameters can be set through our Windows® compatible software (for 32-bit systems) through RS232 communication and an infrared transmitter (software and transmitter not included). HI-141 models feature programmable alarms and logging intervals, and Hanna’s Battery Error Prevention System (BEPS) will shut the meter off when the battery power is too low for an accurate measurement.



PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software directly from equipment via a USB port or a RS232 cable outlet.



Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.

Specifications

Specifications list

Specifications

Model Specific
HI-141AH – Range: -40.0 to 80.0°C/
-40.0 to 176.0°F
 Display No
 Moulded eye for handing Yes
 Sensor(s) 1 internal
Cable length (if applicable) -
HI-141BH – Range: -40.0 to 125.0°C/
-40.0 to 257.0°F
 Display No
 Moulded eye for handing Yes
 Sensor(s) 1 external
Cable length (if applicable) 1m
HI-141CH – Range: -20.0 to 70.0°C/
-40.0 to 158.0°F
 Display Yes
 Moulded eye for handing Yes
 Sensor(s) 1 internal
Cable length (if applicable) -
HI-141DH – Range: -40.0 to 125.0°C/
-40.0 to 257.0°F
 Display Yes
 Moulded eye for handing Yes
 Sensor(s) 1 external
Cable length (if applicable) 1m
HI-141EH – Range: -40.0 to 80.0°C – internal sensor
-40.0 to 175.0°F – internal sensor
-40.0 to 125.0°C – external sensor
-40.0 to 257.0°F – external sensor
 Display No
 Moulded eye for handing Yes
 Sensor(s) 1 Internal
1 External
Cable length (if applicable) 1m
HI-141FH – Range: -40.0 to 125.0°C/
-40.0 to 257.0°F
 Display No
 Moulded eye for handing Yes
 Sensor(s) 2 external
Cable length (if applicable) 1m
HI-141GH – Range: -20.0 to 70.0°C – internal sensor
-40.0 to 158.0°F – internal sensor
-40.0 to 125.0°C – external sensor
-40.0 to 257.0°F – external sensor
 Display Yes
 Moulded eye for handing Yes
 Sensor(s) 1 Internal
1 External
Cable length (if applicable) 1m
HI-141JH – Range: -40.0 to 125.0°C/
-40.0 to 257.0°F
 Display Yes
 Moulded eye for handing Yes
 Sensor(s) 2 external
Cable length (if applicable) 1m
All models
Resolution 0.1°C (-40.0 to 100.0°c); 0.2°C (>100.0°C); 0.1°F (-40.0 to 190.0°F); 0.3°F (>190.0°F)
Accuracy ±0.5°C (-40.0 to 0.0 and 70.0 to 100.0°C); ±0.4°C (0.0 to 70.0°C); ±1.0°C (>100.0°C); ±1.0°F (-40.0 to 32.0 and 158.0 to 212.0°F); ±0.8°F (32.0 to 158.0°F); ±2.0°F (>212.0°F)
Battery Type/Life 3.6V lithium AA battery/approx. life of 4 years at 25°C
Environment RH100%
Diameter 86.5mm
Height 35mm
Weight 150g
Ordering information All HI-141 models are supplied with 3.6 lithium AA battery, magnetic key and instructions
Accessories HI-141000 Windows® compatible software (required)
HI-141001 Infrared transmitter (required)
HI-740033 3.6V AA lithium battery
HI-740221 Key for HI-141 magnetic start

Downloadable Manuals

Manuals

Download PDF

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.