Hanna Instruments

Scientific Equipment

HI-96786C Nitrate Portable Photometer Kit

HI-96786C Nitrate Portable Photometer Kit

Hanna HI-96786C Nitrate Portable Photometer Kit

HI-96786C Nitrate Portable Photometer Kit

Complete with Cal Check standards
2 year manufacturer warranty
In Stock
£692.00 (exc. VAT) £830.40 (inc. VAT)

The HI-96786 portable photometer is for the measurement of Nitrate. The kit contains photometer, CAL CheckTM standards, cuvettes (2) with caps, 9V battery, scissors, cuvette wiping cloth, instrument quality certificate, instruction manual and rigid carrying case.

Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.
Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Frequently Bought Together

Price for all:
£761.50

HI-96786C Nitrate Portable Photometer Kit information

Hanna's extended description

Nitrate is formed in water mainly through rainfall, decomposition of organic matter, and runoff from manmade pollutants such as sewage waste and fertilisers. Almost all surface waters have a measurable level of nitrate, and a moderate amount is considered beneficial. Large amounts of nitrate, however, can lead to eutrophication which may result in decreased levels of dissolved oxygen in the water.


Key features of the Nitrate Portable Photometer

  • Clear display messages make the instrument quick and easy to operate.
  • The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button.
  • Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell.
  • Auto shut off feature turns meter off after 10 minutes of non-use to save battery life.
  • Fully water resistant
  • Clear easy to use function buttons
  • Direct readout of parameter measured

Designed for precision

With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.



Supplied with

  • 2 glass cuvettes, 9V battery

  • NB: reagents ordered separately.

Specifications

Specifications list

Specifications

Range 0.00 to 100mg/L (ppm)
Resolution 1mg/L
Accuracy @25°C ±5mg/L ±5% of reading
Light Source Tungsten lamp
Light Detector Silicon photocell with narrow band interference filter @ 525nm
Power Supply 9V battery
Auto-off After ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°
Dimensions 193 x 104 x 69mm
Weight 360g
Method Adaptation of the cadmium reduction method causes amber tint in sample
Ordering Information HI-96786 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.
Reagents and Standards (sold separately) HI-96786-11 CAL CheckTM standard cuvettes; HI-93728-01 Reagent for 100 tests; HI-93728-03 Reagents for 300 tests

Downloadable Manuals

Manuals

Download PDF

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.