HI-98199 pH, EC, DO digital portable meter (pH electrode included only)
In Stock 2 Items available
HI-98199
The HI-98199 is a versatile meter that can monitor pH, EC, and dissolved oxygen when paired with the respective probe. Hanna’s pH probe is included with the HI-98199 and the EC and DO probes can be ordered separately.
pH electrode included
The HI-98199 allows for the measurement of pH and temperature when used with the included HI-829113 digital pH probe.
- Up to a three-point calibration with five standard buffers and one custom buffer available
- pH in mV option is useful for diagnostics
- GLP data Offset, slope, date, time and buffers used
- Automatically temperature compensated readings
- pH sensor Gel filled and maintenance free
- Double junction for reduced contamination of reference cell
Temperature compensation
- Automatic polarisation of probe at startup
- Ready-to-use HDPE pre-tensioned membrane caps are easy to replace
Backlit Graphic LCD Display
The HI-98199 features a backlit graphic LCD with on-screen help and the capability to display multiple parameters simultaneously. The use of virtual keys to provides for an intuitive user interface.
Waterproof Protection
HI-98199 is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probes feature an IP68 rating for continuous immersion in water.
Quick Connect Digital Probe
pH, EC, and DO probes feature a Quick Connect DIN connector that makes a waterproof connection with the meter.
Auto-sensor Recognition
The probe and meter automatically recognize the sensors that are connected.
Data Logging
The HI-98199 allows users to store up to 45,000 continuous or log-on-demand samples with logging intervals from one second to three hours.
PC Connectivity
Logged data can be transferred to a Window’s compatible PC with the included micro USB cable and Hanna software.
GLP Data
HI-98199 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
Dedicated Help Key
Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
Long Battery Life
The meter displays a battery icon indicator to show the remaining power. The meter uses four 1.5V AA batteries that provide up to 360 hours of battery life.
Versatility when you need it
Each probe transmits readings digitally to the meter, where data points can be displayed and logged.
Conductivity
The HI-98199 allows for the measurement of conductivity, TDS (total dissolved solids), Resistivity, Salinity, seawater σ, and temperature when used with the optional HI-763093 digital EC probe.
- Single-point calibration from six standards
- Temperature compensation Automatic Temperature Compensation
- Configurable temperature coefficient range from 0.00 to 6.00%/°C
- Choice of reference temperatures at 20 or 25°C
- Absolute conductivity can be displayed along with the temperature compensated value
Auto-ranging
Salinity readings Practical Salinity Scale (PSU) based on conductivity calibration
Dissolved Oxygen
The HI-98199 allows for the measurement of dissolved oxygen, atmospheric pressure, and temperature when used with the optional HI-764103 digital DO probe.
- Display units in % saturation or ppm (mg/L)
- Salinity compensation for saline waters Manual entry of salinity values
- Readings compensated for salinity effects
- Built-in barometer Automatic compensation for changes in atmospheric pressure
- User selectable units
HI-98199 Quick Connect
Read More
pH / mV (using the included HI-829113 pH Probe) | ||
Range | 0.00 to 14.00 pH / ±600.0 mV | |
Resolution | 0.01 pH / 0.1 mV | |
Accuracy | ±0.02 pH / ±0.5 mV | |
Calibration | Automatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer | |
EC (using HI-763093 EC Probe – buy separately) | ||
Range | 0 to 200 mS/cm | |
Resolution | manual: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm | |
Accuracy | ±1.5% of reading or ±2 μS/cm whichever is greater | |
Calibration | Automatic single point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point | |
TDS (using HI-763093 EC Probe - buy separately) | ||
Range | 0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor) | |
Resolution | manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L) automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L) | |
Accuracy | ±1% of reading or ±1 ppm (mg/L) whichever is greater | |
Calibration | based on conductivity calibration | |
Resistivity (using HI-763093 EC Probe - buy separately) | ||
Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm | |
Resolution | 1 Ω•cm; 0.1 kΩ•cm; 0.0001 MΩ•cm | |
Calibration | based on conductivity calibration | |
Salinity (using HI-763093 EC Probe – buy separately) | ||
Range | 0.00 to 70.00 PSU | |
Resolution | 0.01 PSU | |
Accuracy | ±2% of reading or ±0.01 PSU whichever is greater | |
Calibration | based on conductivity calibration | |
Seawater σ (using HI-763093 EC Probe – buy separately) | ||
Range | 0.0 to 50.0 σt, σ₀, σ₁₅ | |
Resolution | 0.1 σt, σ₀, σ₁₅ | |
Accuracy | ±1 σt, σ₀, σ₁₅ | |
Calibration | based on conductivity calibration | |
Dissolved Oxygen (using HI-764103 DO Probe - buy separately) | ||
Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) | |
Resolution | 0.1%; 0.01 ppm (mg/L) | |
Accuracy | 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading | |
Calibration | automatic one or two points at 0, 100% or one custom point | |
Atmospheric Pressure (using HI-764103 DO Probe – buy separately) | ||
Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa | |
Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa | |
Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration | |
Calibration | automatic at one custom point | |
Temperature | ||
Range | -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K | |
Resolution | 0.01°C; 0.01°F; 0.01K | |
Accuracy | ±0.15°C; ±0.27°F; ±0.15K | |
Calibration | automatic at one custom point | |
Additional specifications | ||
Temp compensation | automatic from -5 to 55°C (23 to 131°F) | |
Logging Memory | 45000 records (continuous logging or log-on-demand) | |
Logging Interval | one second to three hours | |
PC Connectivity | via USB (with Hanna PC software) | |
Environment | 0 to 50°C (32 to 122°F); RH 100% IP67 | |
Battery Type / Life | 1.5V AA batteries (4) / approximately 400 hours of continuous use without backlight (50 hours with backlight) | |
Dimensions / Weight | 185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4”) / 400 g (14.2 oz.) | |
Ordering Information | HI-98199 is supplied with the HI-829113 pH digital probe with 4m (13’) cable, pH calibration solution sachets, PC software, micro USB cable, batteries, quality certificate, and instruction manual in a rugged carrying case. | |
Probes | HI-829113 pH digital probe with 4m (13’) cable (supplied); HI-763093 EC digital probe with 4m (13’) cable (buy separately); HI-764103 DO digital probe with 4m (13’) cable (buy separately) | |
Accessories | HI-710034 orange protective silicone rubber boot |