HI-96730 Molybdenum Portable Photometer information

Hanna's extended description

Photometer for molybdenum

The HI-96730 measures the molybdenum content in water and wastewater. The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.


The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both, the measurement and the calibration (zeroing) cuvettes, are optically identical to provide the same measurement conditions. Whenever possible use the same cuvette for both. It is necessary that the surface of the cuvette is clean and not scratched to avoid interference due to unwanted reflection and absorption of light. It is recommended not to touch the cuvette walls with hands.


Key features


  • Clear display messages make the instrument quick and easy to operate.
  • The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button.
  • Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell.
  • Auto shut off feature turns meter off after 10 minutes of non-use to save battery life.
  • Fully water resistant
  • Clear easy to use function buttons
  • Direct readout of parameter measured

Designed for precision


With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.


Supplied with


  • 2 glass cuvettes, 9V battery

NB: reagents ordered separately



Specifications

Specifications list

Specifications

Range 0.0 to 40.0 mg/L
Resolution 0.1 mg/L
Accuracy ±0.3 mg/L ±5% of reading
Light Source Tungsten Lamp
Light Detection Silicon Photocell with narrow band interference filter @ 420 nm
Battery Type / Life 1 x 9V / approx. 40 hours of continuous use;
auto-off after 10 minutes of non use
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8")
Weight 360g
Method Adaptation of the mercaptoacetic acid method. The reaction between molybdenum and the reagents causes a yellow tint in the sample

Downloadable Manuals

Manuals

Download PDF

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.