HI-96713C Phosphate Photometer Kit, Low Range

HI-96713C Phosphate Photometer Kit, Low Range

Hanna HI-96713C Phosphate Photometer Kit, Low Range

HI-96713C Phosphate Photometer Kit, Low Range

Complete with Cal Check standards
2 year manufacturer warranty
£552.00 (exc. VAT) £662.40 (inc. VAT)
Kit including HI-96713 photometer, hard carrying case, 2 sample cuvettes, scissors, cuvette cleaning cloth, battery, instruction manual and CAL CHECK standards for phosphate LR. Testing reagents sold separately.
Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.
Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Frequently Bought Together

Price for all:
£582.55

HI-96713C Phosphate Photometer Kit, Low Range information

Hanna's extended description

Kit including HI-96713 photometer, hard carrying case, 2 sample cuvettes, scissors, cuvette cleaning cloth, battery, instruction manual and CAL CHECK standards for phosphate LR. Testing reagents sold separately.


About the photometer for phosphate, low range

The HI-96713 measures phosphate content in water, wastewater and seawater in the 0.00 to 2.50 mg/L (ppm) range.

Phosphates are particularly important for the growth and development of plant roots, and hence are one of the most common fertilisers used in agriculture. Phosphates are also utilised in detergents and are needed, in small quantities, for heating systems. However, high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication.

For these reasons, it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water.


Key features


  • Clear display messages make the instrument quick and easy to operate.
  • The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button.
  • Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell.
  • Auto shut off feature turns meter off after 10 minutes of non-use to save battery life.
  • Fully water resistant
  • Clear easy to use function buttons
  • Direct readout of parameter measured
  • Calibration check solution available - HI 96713-11

Designed for precision

With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.


All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.



Order information

  • Full kit (HI-96713C): 2 glass cuvettes, 9V battery, attaché case, calibration check standards, cleaning cloths

NB: reagents ordered separately

Specifications

Specifications list

Specifications

Range 0.00 to 2.50 mg/L (ppm)
Resolution 0.01 mg/L (ppm)
Precision ±0.04 mg/L ±4% of reading
Light Source Tungsten lamp
Light Detector Silicon photocell with narrow band interference filter @ 610 nm
Method Adaptation of the ascorbic acid method.
Ordering information HI-96713 is supplied with a photometer, sample cuvettes (2) with caps, 9v battery, instrument quality certificate and instruction manual.
Reagents and Standards HI-96713-11 CAL CheckTM standard cuvettes; HI-93713-01 reagents for 100 tests; HI-93713-03 reagents for 300 tests
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
Interference may be caused by: Iron above 50 mg/L
Silica above 50 mg/L
Silicate above 10 mg/L
Copper above 10 mg/L
Hydrogen sulphide, arsenate, turbid sample and highly buffered samples also interfere.

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.