HI-96718 Iodine Portable Photometer

HI-96718 Iodine Portable Photometer

Hanna HI-96718 Iodine Portable Photometer

HI-96718 Iodine Portable Photometer

Complete with cuvettes
2 year manufacturer warranty
In Stock
£288.00 (exc. VAT) £345.60 (inc. VAT)

The HI-96718 measures the Iodine content in water samples in the 0.0 to 12.5 mg/L (ppm) range.

HI-96718 Iodine Portable Photometer information

Hanna's extended description

Iodine portable photometer



The HI-96718 measures the Iodine content in water samples in the 0.0 to 12.5 mg/L (ppm) range.

Offering high levels of accuracy as well as being water resistant, portable and easy to use, this meter is hugely popular and is the optimum solution for quick, efficient and economical total hardness and pH measurement.

The disinfectant properties of Iodine have led to its use as an alternative to chlorine and bromine. Unlike chlorinated pools, water treated with iodine decreases eye irritation among swimmers, and provides a level of disinfection more stable to adverse conditions. However, its toxic and corrosive properties and the difficulties of dissolving it in water has limited its widespread acceptance.

This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results.



Key features


  • Clear display messages make the instrument quick and easy to operate
  • The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button
  • Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell
  • Auto shut off feature turns meter off after 10 minutes of non-use to save battery life
  • Fully water resistant
  • Clear easy to use function buttons
  • Direct readout of parameter measured
  • Calibration check solution available - HI 96702-11

Designed for precision


With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.



Order information


  • Meter only (HI -96718): 2 glass cuvettes, 9V battery
  • Full kit (HI-96718C): 2 glass cuvettes, 9V battery, attaché case, calibration check standards, cleaning cloths

NB: reagents ordered separately





Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.



Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Specifications

Specifications list

Specifications

Range 0.0 to 12.5 mg/L (ppm)
Resolution 0.1 mg/L (ppm)
Precision ±0.1 mg/L ±5% of reading
Light Source Tungsten lamp
Light Detector Silicon photocell with narrow band interference filter @ 525 nm
Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed.
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
Interference may be caused by: Bromine, Chlorine, Ozone, oxidised forms of chromium and manganese. Alkalinity above 250 mg/L and acidity above 150 mg/L as CaCO3 require neutralisation since the colour could instantly fade. To resolve this, neutralise the sample with diluted HCl or NaOH. In case of water with hardness greater than 500 mg/L CaCO3, shake the sample for approximately 2 minute after adding the reagent. Alternatively, wait for 2 minutes and 30 seconds then just press READ/TIMER. In both cases, the lamp, cuvette and detector icons will appear on the display, depending on the measurement phase.

Downloadable Manuals

Manuals

Download PDF

Product Literature

literature - PDF