Hanna Instruments

Scientific Equipment

HI-84530-02 Automatic Benchtop Mini Titrator for Total Titratable Acidity and Titratable Alkalinity

HI-84530-02 Automatic Benchtop Mini Titrator for Total Titratable Acidity and Titratable Alkalinity

Hanna HI-84530-02 Automatic Benchtop Mini Titrator for Total Titratable Acidity and Titratable Alkalinity

HI-84530-02 Automatic Benchtop Mini Titrator for Total Titratable Acidity and Titratable Alkalinity

In Stock
£1,677.40 (exc. VAT) £2,012.88 (inc. VAT)

The HI-84530-02 is an easy to use, fast and affordable, method specific titrator designed for testing titratable acidity levels in water. Based on an acid-base titration method, this mini titrator uses an optimised pre-programmed method of analysis with a powerful algorithm that determines the completion of the titration reaction potentiometrically with a glass body pH electrode.

The HI-84530-02 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage change. This type of dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.

HI-84530-02 Automatic Benchtop Mini Titrator for Total Titratable Acidity and Titratable Alkalinity information

Hanna's extended description

This mini titrator is supplied complete with all the materials necessary to perform low and high range measurements of acidity in water. All chemicals are pre-mixed and pre-packaged including standardised titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.


  • Piston driven pump for accurate dynamic dosing
  • Pre-standardised titrant and pre-measured reagents
  • Benchtop use as a pH/mV meter
  • Acidity


    Acidity is an important parameter used to determine the quality of water (surface, drinking, wastewater). Acidity affects many things including chemical reaction rates, biological processes, and corrosive behaviour. It can also be used to monitor pollution in wastewater and drinking water.

    Total titratable acidity is a quantitative measurement of the water sample’s ability to react with a strong base solution to a specific pH value. Many chemical species can contribute to the acidity measurement depending on the method of analysis. These species can include strong acids (hydrochloric acid, nitric acid, sulphuric acid, etc.), weak acids (acetic acid, carbonic acid, etc.), and hydrolysing salts (iron, aluminium, manganese, etc.)


    On-Screen Features



    Tutorial and Help Screens

    The HI-84530 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.


    Procedure Warnings

    Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.





    Titration Curve Displayed on Screen

    This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.


    Log and Recall Data

    The HI-84530 allows for data logging of up to 400 samples: 200 titration results and 200 pH/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.


    pH/mV Meter

    In addition to being an automatic titrator, the HI-84530 also can be used as a pH/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.





    CAL Check™

    Accuracy is always ensured with Hanna’s unique CAL Check feature, which analyses the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI-84530 is used as a pH meter, but also an accurate titration since the endpoint of a titratible acidity titration is determined by a set pH value.

    Specifications

    Specifications list

    Specifications

    Range Low Range (as CaCO₃): 15.0 to 400.0 mg/L; 0.3 to 8.0 meq/L
    High Range (as CaCO₃): 300 to 4000 mg/L; 6.0 to 80.0 meq/L
    Resolution Low Range: 0.1 mg/L / 0.1 meq/L; High Range: 1 mg/L / 0.1 meq/L
    Accuracy (@25˚C) Low Range: ±0.5 mg/L or 3% of reading, whichever is greater; High Range: ±15 mg/L or 3% of reading, whichever is greater
    Methods Acid base titration, total acidity / strong acidity
    Principle Fixed endpoint titration: 8.30 pH (phenolphthalein) or 3.7 pH (methyl orange)
    Pump speed 10 mL/min
    Stirring speed 600 rpm
    pH Range -2.0 to 16.0 pH; -2.00 to 16 pH
    pH Resolution 0.1 pH/0.01pH
    pH Accuracy (@25˚C) ±0.01pH
    pH Calibration one, two or three-point calibration; four available buffers (4.01, 7.01, 8.30, 10.01)
    Temperature compensation manual or automatic
    mV Range -2000.0 to 2000.0 mV
    mV Resolution 0.1 mV
    mV Accuracy (@25˚C) ±1.0 mV
    Temperature Range -20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K
    Temperature Resolution 0.1˚C;
    Temperature Accuracy (@25˚C) ±0.4˚C
    Logging Data up to 400 (200 titrations, 200 pH/mV readings)
    Electrode HI-1131B glass body, refillable, with BNC connector and 1m (3.3’) cable (included)
    Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Power Supply 12 VDC adapter (included)
    Dimensions 235 x 200 x 150 mm
    Weight 1.9 kg
    Ordering Information HI-84530 is supplied with the HI-1131B pH electrode, HI-7662-T temperature probe, HI-84530-50 low range titrant, HI-84530-51 high range titrant, HI-84530-55 calibration standard, HI-84530-60 hydrogen peroxide, 100 mL beakers (2), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, power adapter, instruction manual and quality certificate.
    Warranty Titrator 2 years, Electrode 6 months

    Product Literature

    literature - PDF

    Hanna Instruments Literature

    Questions & Answers

    Got a question to ask? Use this form to submit your question.
    Question will be displayed after moderation.
    Name* Product Question*
    No questions yet?
    Don 't be shy, be the first to ask.