HI-96722 Cyanuric Acid Portable Photometer

HI-96722 Cyanuric Acid Portable Photometer

HI-96722 Cyanuric Acid Portable Photometer

HI-96722 Cyanuric Acid Portable Photometer

Complete with cuvettes
2 year manufacturer warranty
£274.50 (exc. VAT) £329.40 (inc. VAT)

Cyanuric acid ion specific meter - supplied with 2 cuvets and caps.

HI-96722 Cyanuric Acid Portable Photometer information

Hanna's extended description

Cyanide Portable Photometer


The HI-96722 meter measures the cyanuric acid content in water samples in the 0 to 80 mg/L (ppm) range.

This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.

Cyanuric acid (CYA) is best known as a stabilising reagent for chlorine. It is widely applied in swimming pool and spa treatment programs to slow down the decomposition of hypochlorous acid. In outside pool areas, this process is accelerated by the effects of UV rays. When applied properly it can save up to 80% of normal chlorine consumption in pools during peak months.

Cyanuric acid is also used in chlorinated beaches, selective herbicides and whitening agents.


Key features


  • Clear display messages make the instrument quick and easy to operate
  • The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button
  • Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell
  • Auto shut off feature turns meter off after 10 minutes of non-use to save battery life
  • Fully water resistant
  • Clear easy to use function buttons
  • Direct readout of parameter measured

Designed for precision


With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.



Order information


  • Meter only (HI -96722): 2 glass cuvettes, 9V battery

NB: reagents ordered separately





Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.



Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Specifications

Specifications list

Specifications

Range 0 to 80 mg/L
Resolution 1 mg/L
Accuracy @ 25°C 1mg/L ±15% of reading
Light Source Tungsten lamp
Light detector Silicon photocell with narrow band interference filter @525nm
Method Adaption of the turbidmetric method. The reaction between cyanuric acid and the reagent causes a white suspension in the sample.
Environment 0 to 50° C max 95% RH non-condensing
Battery type 9V (1)
Auto-shut off after 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode with last reading reminder
Dimensions 192 x 104 x 69 mm
Weight 320g

Downloadable Manuals

Manuals

Download PDF

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.