Hanna Instruments

Scientific Equipment

HI-8936CLN Conductivity Transmitter

HI-8936CLN Conductivity Transmitter

HI-8936CLN Conductivity Transmitter

HI-8936CLN Conductivity Transmitter

Use with HI-7635 or HI-7638
2 year manufacturer warranty
£454.50 (exc. VAT) £545.40 (inc. VAT)

HI-8936 is a conductivity transmitter that utilises a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.

  • Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations
  • Optional backlit, LCD display for easy viewing
  • Mains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz.
    Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

    Frequently Bought Together

    Price for all:
    £598.50

    HI-8936CLN Conductivity Transmitter information

    Hanna's extended description

    Conductivity Transmitter Using 4-Ring Technology, range: 0 to 1999 µS/cm; with LCD display.

    Easy Installation

    The HI-8936 transmitter may be wall-mounted at any convenient location close to the measurement site. The HI-8936 series should be used in conjunction with the HI-7635 in-line probe or HI-7638 platinum probe.


    Optional LCD

    HI-8936”L” versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.


    Automatic Temperature Compensation

    Temperature effects are compensated for by utilising both the built-in temperature sensor on the probe and the transmitter’s ATC circuitry with a of 2%/°C.


    Direct Probe Connection

    Direct connection of the probe to the transmitter assures a positive electrical connection with no signal loss over long distances.

    Specifications

    Specifications list

    Specifications

    EC Range HI-8936AN & ALN: 0.0 to 199.9 mS/cm
    HI-8936BN & BLN: 0.00 to 19.99 mS/cm
    HI-8931CN & CLN: 0 to 1999 µS/cm
    HI-8931DN & DLN: 0.0 to 199.9 µS/cm
    EC Resolution HI-8936AN & ALN: 0.1 mS/cm
    HI-8931BN & BLN: 0.01 mS/cm
    HI-8931CN & CLN: 1 µS/cm
    HI-8931DN & DLN: 0.1 µS/cm
    EC Accuracy ±2% F.S. (excluding probe error)
    EC Calibration manual, two point, through offset and slope trimmers
    EC/TDS Temperature Compensation fixed or automatic from 0 to 50°C (32 to 122°F) with β=2%/°C
    EC/TDS Probe HI-7635 for in-line applications (not included)
    Recorder Output 4-20 mA, not isolated, max 500 Ohm
    LCD Display AN, BN, CN & DN = No
    ALN, BLN, CLN, & DLN = Yes
    Power Supply without LCD: 12-30 VDC; with LCD: 17-36 VDC
    Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
    IP Rating IP65
    Dimensions 165 x 110 x 71 mm (6.5 x 4.3 x 2.8’’)
    Weight 1KG
    Ordering Information The HI-8936 series is supplied with instructions

    Downloadable Manuals

    Manuals

    Download PDF

    Product Literature

    literature - PDF

    Hanna Instruments Literature

    Questions & Answers

    Got a question to ask? Use this form to submit your question.
    Question will be displayed after moderation.
    Name* Product Question*
    No questions yet?
    Don 't be shy, be the first to ask.