Hanna Instruments

Scientific Equipment

HI-96762C Free Chlorine Photometer Kit, Low Range

HI-96762C Free Chlorine Photometer Kit, Low Range

HI-96762C Free Chlorine Photometer Kit, Low Range

HI-96762C Free Chlorine Photometer Kit, Low Range

Complete with Cal Check standards
2 year manufacturer warranty
£548.00 (exc. VAT) £657.60 (inc. VAT)

Chlorine Free Drinking Meter Colorimeter, supplied with 2 cuvettes & Caps, 9v battery, Scissors, tissue for cleaning cuvettes, Instruction manual and rigid carry case. The Hanna HI-96762 is an auto-diagnostic portable photometer for accurately measuring Free Chlorine.

Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.
Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Frequently Bought Together

Price for all:
£766.50

HI-96762C Free Chlorine Photometer Kit, Low Range information

Hanna's extended description

Photometer for Free Chlorine, low range



The HI-96762 meter measures the traces of free chlorine content in drinking water samples.

Offering high levels of accuracy as well as being water resistant, portable and easy to use, this meter is hugely popular with operators across the water industry. A measurement range of 0.000 to 0.500 ppm free chlorine makes it the optimum solution for quick, efficient and economical free chlorine measurement.

Also available as a full kit HI-96762C - scroll to bottom of page for further details


Ideal for

  • Water: measuring chlorine content in drinking water samples

Key features


  • Clear display messages make the instrument quick and easy to operate.
  • The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button.
  • Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell.
  • Auto shut off feature turns meter off after 10 minutes of non-use to save battery life.
  • Fully water resistant
  • Clear easy to use function buttons
  • Direct readout of parameter measured
  • Calibration check solution available - HI 96762-11

Designed for precision

With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.


Order information

  • Meter only (HI -96762): 2 glass cuvettes, 9V battery
  • Full kit (HI-96762C): 2 glass cuvettes, 9V battery, attaché case, calibration check standards, cleaning cloths

NB: reagents ordered separately



Specifications

Specifications list

Specifications

Parameter Chlorine, Free ULR
Range 0.000 to 0.500 mg/L
Accuracy ±0.001 mg/L @ 0.020 mg/L +-3% of reading
Filter Narrow band @ 525 nm
Method Adaptation of Standard Methods, 20th edition, 4500-Cl G. The reaction between chlorine and the DPD reagent causes a pink tint in the sample.
Environment 0 to 50°C (32 to 122°F); Max 95% RH non-condensing
Battery Type / Life (1) 9V
Auto Shut-off After 10 min. of non-use in measurement mode
Dimensions 193 x 104 x 69 mm
Weight 360g
Ordering Information HI-96762 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.
Reagents and Standards (sold separately) HI-96762-11 CAL CheckTM standard cuvettes; HI-95762-01 Reagent for 100 tests; HI-95762-03 Reagents for 300 tests
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
Interferences may be caused by:
  • Alkalinity: above 1,000 mg/L CaCO3 if present as bicarbonate (HCO3 sample pH < 8.3); above 25 mg/L CaCO3 if present as carbonate (CO32-, sample pH > 9.0). In both cases, it will not reliably develop the full amount of colour, or it may rapidly fade (negative 15 error). To resolve this, neutralise the sample with diluted HCl.

  • Acidity: above 150 mg/L CaCO3. May not be reliably develop the full amount of colour, or it may rapidly fade (negative error). To resolve this, neutralise the sample with diluted NaOH.

  • Hardness: in case of water with hardness greater than 500mg/L CaCO3, shake the sample for approximately 2 minutes after adding the powder reagent.

  • Bromine (Br2): positive error
    Chloride dioxide (ClO2): positive error
    Iodine (I2): positive error
    Oxidized Manganese and Chromium: positive error
    Ozone (O3): positive error

    Downloadable Manuals

    Manuals

    Download PDF

    Product Literature

    literature - PDF

    Hanna Instruments Literature

    Questions & Answers

    Got a question to ask? Use this form to submit your question.
    Question will be displayed after moderation.
    Name* Product Question*
    No questions yet?
    Don 't be shy, be the first to ask.