HI-93701-01 Free Chlorine Reagent, DPD Method

HI-93701-01 Free Chlorine Reagent, DPD Method

Hanna HI-93701-01 Free Chlorine Reagent, DPD Method

HI-93701-01 Free Chlorine Reagent, DPD Method

100 tests
Range: 0.00 to 2.50 mg/L
In Stock
£28.50 (exc. VAT) £34.20 (inc. VAT)

The HI-93701-01 are reagents for the colorimetric determination of free chlorine. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.

  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • HI-93701-01 Free Chlorine Reagent, DPD Method information

    Hanna's extended description

    The HI-93701-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. The intensity of colour is determined by a compatible photometer and the concentration will be displayed. The results will be display the concentration of chlorine in mg/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg/L free chlorine.

    Tip for an accurate measurement

    It is important that the sample does not contain any debris.

    When the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.

    Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.

    Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.

    After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.



    Ideal accessory: HI-731318 Cuvette cleaning cloths x 4

    Specifications

    Specifications list

    Specifications

    Package packets
    Quantity 100 tests
    Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and the reagents causes a pink tint in the sample.