Hanna Instruments

Scientific Equipment

HI-96700C Ammonia Portable Photometer Kit, low range

HI-96700C Ammonia Portable Photometer Kit, low range

HANNA HI-96700C Ammonia Portable Photometer Kit

HI-96700C Ammonia Portable Photometer Kit, low range

Complete with Cal Check standards
2 year manufacturer warranty
In Stock
£531.50 (exc. VAT) £637.80 (inc. VAT)

The portable photometer is for the measurement of ammonia nitrogen in fresh & salt water samples.

Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.

Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.

Frequently Bought Together

Price for all:
£582.00

HI-96700C Ammonia Portable Photometer Kit, low range information

Hanna's extended description

HI-96700C Ammonia Portable Photometer Kit

Present naturally in surface and wastewaters, ammonia mainly results from the deamination of organic nitrogen-containing compounds and hydrolysis of urea. Ammonia may also be present from water treatment processes that utilise chloramines for disinfection, where ammonia is added to the water to react with chlorine. Ammonia is less likely to appear in groundwater due to absorption to soil particles.


  • CAL Check - Allows for performance verification and calibration of the meter using NIST traceable standards
  • GLP – Review of the last calibration date
  • Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on
  • Battery status indicator – Indicates the amount of battery life left
  • Built-in timer – Display of time remaining before a measurement is taken. Ensures that all reading are taken at the appropriate reaction intervals for the test being performed
  • Error message – Messages on display alerting to problems including no cap, high zero, and standard too low
  • Cooling lamp indicator – To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken
  • Units of measurement – Appropriate unit of measure is displayed along with reading

Specifications

Specifications list

Specifications

Range 0.00 to 3.00 mg/L (ppm)
Resolution 0.01 mg/L (ppm)
Precision ±0.04 mg/L (ppm) ±4% of reading
Light Source Tungsten lamp
Light Detector Silicon photocell with narrow band interference filter (@ 420 nm for HI-96700 and HI-96733)
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply (1) 9V battery
Auto-off After 10 minutes of non-use in measuring mode After 1 hour of non-use in calibration mode with last reading reminder
Dimensions 193 x 104 x 69 mm
Weight 360g
Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler method.
Reagents and Standards HI-96700-11 CAL-Check standards cuvettes; HI-93700-01 Reagents for 100 tests (NH3 LR); HI-93700-03 Reagents for 300 tests (NH3 LR);
Kit contains: Includes photometer, CAL Check Standards, sample cuvettes (2) with caps, 9V battery, cuvette wiping cloth, instrument quality certificate, instruction manual and rigid carrying case.
INTERFERENCES
 Interference may be caused by: Hardness above 1 g/L
Iron
Sulphide
Glycine
Various aliphatic and aromatic amines
Organic chloramines; acetone
Aldehydes
alcohols

Product Literature

literature - PDF

Hanna Instruments Literature

Questions & Answers

Got a question to ask? Use this form to submit your question.
Question will be displayed after moderation.
Name* Product Question*
No questions yet?
Don 't be shy, be the first to ask.