HI-93700-01 Ammonia Low Range Reagents

HI-93700-01 Ammonia Low Range Reagents

Hanna HI-93700-01 Ammonia Low Range Reagents

HI-93700-01 Ammonia Low Range Reagents

100 tests
Range: 0.00 to 3.00 mg/L
In Stock
£51.45 (exc. VAT) £61.74 (inc. VAT)

HI-93700-01 Ammonia Low Range Reagents information

Hanna's extended description

The HI-93700-01 are reagents for the colorimetric determination of ammonia in freshwater. There are enough reagents for 100 tests and are for use with Hanna Instruments compatible benchtop and portable meters. These high quality liquid reagents are clearly marked with the lot number and expiry date for traceability on each bottle.


  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • The HI-93700-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Nessler Method in which the reaction between ammonia and reagents causes a yellow tint in the sample. By simply adding 4 drops from each bottle of HI-93700-01 reagent set to the sample, the reaction between ammonia and reagents causes a yellow tint in the sample will take place. The intensity of colour is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in ppm (mg/L) of either ammonia-nitrogen (NH3-N), ammonia or ammonium based on meter and setting being used. These reagents are designed to be used with samples that have an expected range of 0.00 to 3.00 ppm ammonia-nitrogen.

    Please note: this reagent in not recommended for saltwater applications.

    Specifications

    Specifications list

    Specifications

    Package dropper bottles “A” and “B”
    Quantity 100 tests
    Method adaptation of the ASTM Manual of Water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.