Hanna Instruments

Scientific Equipment

HI-801-02 Iris Spectrophotometer

HI-801-02 Iris Spectrophotometer

Hanna HI-801-02 Iris Spectrophotometer
Hanna HI-801-02 Iris Spectrophotometer Hanna Hi-801-02 iris Spectrophotometer

HI-801-02 Iris Spectrophotometer

precise wavelength between 340 nm to 900 nm
Wavelength Accuracy ±1.5 nm
In Stock
£2,495.00 (exc. VAT) £2,994.00 (inc. VAT)

The HI-801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.

Customise your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.

  • iris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more.
  • Results are consistent and accurate regardless of throughput with the high quality and uniquely designed optics system.
  • Customisation options include multiple cuvette shapes and sizes, custom calibration curves, and methods.
  • The 6 inch display screen is large and easy to read. The high contrast makes every character on the display stand out - even during outdoor use.

    With its universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed between round, square & vial.

    Frequently Bought Together

    Price for all:
    £2,540.25
    Buy All 3 for: £2,413.24

    HI-801-02 Iris Spectrophotometer information

    Hanna's extended description

    Superior design for superior results

    iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.

    With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.


    No need for measurement conversions

    Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.

    Worry free replacements

    iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.


    Designed for dynamic environments

    iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.

    Quality data without the hassle

    Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.

    Sort and share your data

    Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that is best for you.


    Menu navigation that makes sense

    Quickly navigate between screens with custom keys, and access your favourite methods directly from the home screen with our “favourite methods” feature.

    All of your important information is easily visible

    With a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.





    Zero resistance with a capacitive touch pad

    Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognises key touches even through gloves.



    Change sample size easily

    With its universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.

    Specifications

    Specifications list

    Specifications

    Wavelength Range 340 to 900 nm
    Wavelength Resolution 1 nm
    Wavelength Accuracy ±1.5 nm
    Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, °f, °e, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, °dH, meq/kg or no measurement unit)
    Wavelength Selection automatic, based on the selected method (editable for user methods only)
    Light Source tungsten halogen lamp
    Optical System split beam sample and reference light detectors
    Wavelength Calibration Internal, automatic at power-on, visual feedback
    Stray Light <0.1 % T at 340 nm with NaNO2
    Spectral bandwidth 5 nm (full width at half maximum)
    Sample Cell 16 mm round, 22 mm round, 13 mm vial, 10 mm square, 50 mm rectangular (with automatic detection)
    Programs (Factory/User) Up to 150 factory (85 pre-loaded); up to 100 user developed
    Data Points Stored Up to 9999 measured values
    Export Capability .csv file format, .pdf file format
    Connectivity (1) USB - A (mass storage host); (1) USB - B (mass storage device)
    Battery Type / Life 3000 measurements or 8 hours
    Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
    Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH
    Dimensions 155 x 205 x 322 mm
    Weight 3 kg (6.6 lbs)
    Ordering Information HI-801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.
    ABSORBANCE
     Range 0.000 to 3.000 Abs
     Resolution 0.001 Abs
     Accuracy (@25°C) 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs
    ALKALINITY
     Range 0 to 500 mg/L (as CaCO3 )
     Resolution 1 mg/L
     Accuracy (@25°C) ±5 mg/L ±5% of reading
     Method Colorimetric Method
     Wavelength 610 nm
     Reagent Code HI-775-26
    ALKALINITY, MARINE
     Range 0 to 300 mg/L (as CaCO3 )
     Resolution 1 mg/L
     Accuracy (@25°C) ±5 mg/L ±5% of reading
     Method Colorimetric Method
     Wavelength 610 nm
     Reagent Code HI-755-26
    ALUMINIUM
     Range 0.00 to 1.00 mg/L (as Al3+)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.04 mg/L ±4% of reading
     Method Adaptation of the aluminon method
     Wavelength 525 nm
     Reagent Code HI-93712-01
    AMMONIA, LOW RANGE
     Range 0.00 to 3.00 mg/L (as NH3 -N)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.04 mg/L ±4% of reading
     Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.
     Wavelength 420 nm
     Reagent Code HI-93700-01
    AMMONIA, MEDIUM RANGE
     Range 0.00 to10.00 mg/L (as NH3 -N)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.05 mg/L ±5% of reading
     Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method
     Wavelength 420 nm
     Reagent Code HI-93715-01
    AMMONIA, HIGH RANGE
     Range 0.0 to 100.0 mg/L (as NH3 -N)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.5 mg/L ±5% of reading
     Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method
     Wavelength 420 nm
     Reagent Code HI-93733-01
    BROMINE
     Range 0.00 to 8.00 mg/L (as Br2 )
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.08 mg/L ±3% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
     Wavelength 525 nm
     Reagent Code HI-93716-01
    CALCIUM
     Range 0 to 400 mg/L (as Ca2+)
     Resolution 1 mg/L
     Accuracy (@25°C) ±10 mg/L ±5% of reading
     Method Adaptation of the Oxalate method
     Wavelength 466nm
     Reagent Code HI-937521-01
    CALCIUM, MARINE
     Range 200 to 600 mg/L (as Ca2+)
     Resolution 1 mg/L
     Accuracy (@25°C) ±6% of reading
     Method Adaptation of the Zincon method
     Wavelength 610 nm
     Reagent Code HI-758-26
    CHEMICAL OXYGEN DEMAND
     LOW RANGE
     Range 0 to 150 mg/L (as O2 )
     Resolution 1 mg/L
     Accuracy (@25°C) ±5 mg/L or ±4% of reading
     Method Adaptation of the USEPA 410.4
     Wavelength 420 nm
     Reagent Code HI-93754A-25
    CHEMICAL OXYGEN DEMAND
     MEDIUM RANGE
     Range 0 to 1500 mg/L (as O2)
     Resolution 1 mg/L
     Accuracy (@25°C) ±15 mg/L or ±4% of reading
     Method Adaptation of the USEPA 410.4
     Wavelength 610 nm
     Reagent Code HI-93754B-25
    CHEMICAL OXYGEN DEMAND
     HIGH RANGE
     Range 0 to 15000 mg/L (as O2 )
     Resolution 1 mg/L
     Accuracy (@25°C) ±150 mg/L or ±2% of reading
     Method Adaptation of the USEPA 410.4
     Wavelength 610 nm
     Reagent Code HI-93754C-25
    CHLORIDE
     Range 0.0 to 20.0 mg/L (as Cl)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.5 mg/L ±6% of reading
     Method Adaptation of the mercury(II) thiocyanate method
     Wavelength 466 nm
     Reagent Code HI-93753-01
    CHLORINE DIOXIDE
     Range 0.00 to 2.00 mg/L (as ClO2 )
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.10 mg/L ±5% of reading
     Method Adaptation of the Chlorophenol Red method
     Wavelength 575 nm
     Reagent Code HI-93738-01
    CHLORINE, FREE ULTRA LOW RANGE
     Range 0.000 to 0.500 mg/L (as Cl2 )
     Resolution 0.001 mg/L
     Accuracy (@25°C) ±0.020 mg/L ±3% of reading
     Method Adaptation of the Standard Method 4500-Cl G
     Wavelength 525 nm
     Reagent Code HI-95762-01
    CHLORINE, FREE LOW RANGE
     Range 0.00 to 5.00 mg/L (as Cl2)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the EPA DPD method 330.5
     Wavelength 525 nm
     Reagent Code HI-93701-01
    CHLORINE, FREE HIGH RANGE
     Range 0.00 to 10.00 mg/L (as Cl2)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the EPA DPD method 330.5
     Wavelength 525 nm
     Reagent Code HI-93734-01
    CHLORINE, TOTAL ULTRA LOW RANGE
     Range 0.000 to 0.500 mg/L (as Cl2 )
     Resolution 0.001 mg/L
     Accuracy (@25°C) ±0.020 mg/L ±3% of reading
     Method Adaptation of the EPA recommended Method 330.5
     Wavelength 525 nm
     Reagent Code HI-95761-01
    CHLORINE, TOTAL LOW RANGE
     Range 0.00 to 5.00 mg/L (as Cl2)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the EPA DPD method 330.5
     Wavelength 525 nm
     Reagent Code HI-93711-01
    CHLORINE, TOTAL HIGH RANGE
     Range 0.00 to 10.00 mg/L (as Cl2)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the EPA DPD method 330.5
     Wavelength 525 nm
     Reagent Code HI-93734-01
    CHLORINE, TOTAL ULTRA HIGH RANGE
     Range 0 to 500 mg/L (as Cl2)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl
     Wavelength 525 nm
     Reagent Code HI-95771-01
    CHROMIUM (VI), LOW RANGE
     Range 0 to 300 µg/L (as Cr(VI))
     Resolution 1 µg/L
     Accuracy (@25°C) ±10 µg/L ±4% of reading
     Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method
     Wavelength 525 nm
     Reagent Code HI-93749-01
    CHROMIUM (VI), HIGH RANGE
     Range 0 to 1000 µg/L (as Cr(VI))
     Resolution 1 µg/L
     Accuracy (@25°C) ±5 µg/L ±4% of reading
     Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method
     Wavelength 525 nm
     Reagent Code HI-93723-01
    COLOUR OF WATER
     Range 0 to 500 PCU (Platinum Cobalt Units)
     Resolution 1 PCU
     Accuracy (@25°C) ±10 PCU ±5% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method
     Wavelength 420 nm
     Reagent Code
    COPPER, LOW RANGE
     Range 0.000 to 1.500 mg/L (as Cu)
     Resolution 0.001 mg/L
     Accuracy (@25°C) ±0.010 mg/L ±5% of reading
     Method Adaptation of the EPA method
     Wavelength 575 nm
     Reagent Code HI-95747-01
    COPPER, HIGH RANGE
     Range 0.00 to 5.00 mg/L (as Cu)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.02 mg/L ±4% of reading
     Method Adaptation of the EPA method
     Wavelength 575 nm
     Reagent Code HI-93702-01
    CYANIDE
     Range 0.000 to 0.200 mg/L (as CN-)
     Resolution 0.001 mg/L
     Accuracy (@25°C) ±0.005 mg/L ±3% of reading
     Method Pyridine-Pyrazalone
     Wavelength 610 nm
     Reagent Code HI-93714-01
    CYANURIC ACID
     Range 0 to 100 mg/L (as CYA)
     Resolution 1 mg/L
     Accuracy (@25°C) ±1 mg/L ±15% of reading
     Method Adaptation of the turbidimetric method
     Wavelength 525 nm
     Reagent Code HI-93722-01
    FLUORIDE, LOW RANGE
     Range 0.00 to 2.00 mg/L (as F)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
     Wavelength 575 nm
     Reagent Code HI-93729-01
    FLUORIDE, HIGH RANGE
     Range 0.0 to 20.0 mg/L (as F)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.5 mg/L ±3% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
     Wavelength 575 nm
     Reagent Code HI-93739-01
    HARDNESS, CALCIUM
     Range 0.00 to 2.70 mg/L (as CaCO3)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.11 mg/L ±5% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
     Wavelength 525 nm
     Reagent Code HI-93720-01
    HARDNESS, MAGNESIUM
     Range 0.00 to 2.00 mg/L (as CaCO3)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.11 mg/L ±5% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
     Wavelength 525 nm
     Reagent Code HI-93719-01
    HARDNESS, TOTAL LOW RANGE
     Range 0.00 to 250 mg/L (as CaCO3)
     Resolution 1 mg/L
     Accuracy (@25°C) ±5 mg/L ±4% of reading
     Method Adaptation of the EPA recommended method 130.1
     Wavelength 466 nm
     Reagent Code HI-93735-00
    HARDNESS, TOTAL MEDIUM RANGE
     Range 200 to 500 mg/L (as CaCO3)
     Resolution 1 mg/L
     Accuracy (@25°C) ±7 mg/L ±3% of reading
     Method Adaptation of the EPA recommended method 130.1
     Wavelength 466 nm
     Reagent Code HI-93735-01
    HARDNESS, TOTAL HIGH RANGE
     Range 400 to 750 mg/L (as CaCO3)
     Resolution 1 mg/L
     Accuracy (@25°C) ±10 mg/L ±2% of reading
     Method Adaptation of the EPA recommended method 130.1
     Wavelength 466 nm
     Reagent Code HI-93735-02
    HYDRAZINE
     Range 0 to 400 µg/L (as N2H4 )
     Resolution 1 µg/L
     Accuracy (@25°C) ±4% of full scale reading
     Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method
     Wavelength 466 nm
     Reagent Code HI-93704-01
    IODINE
     Range 0.0 to 12.5 mg/L (as I2)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.1 mg/L ±5% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
     Wavelength 525 nm
     Reagent Code HI-93718-01
    IRON, LOW RANGE
     Range 0.000 to 1.600 mg/L (as Fe)
     Resolution 0.001 mg/L
     Accuracy (@25°C) ±0.010 mg/L ±8% of reading
     Method Adaptation of the TPTZ Method
     Wavelength 575 nm
     Reagent Code HI-93746-01
    IRON, HIGH RANGE
     Range 0.00 to 5.00 mg/L (as Fe)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.04 mg/L ±2% of reading
     Method Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters
     Wavelength 525 nm
     Reagent Code HI-93721-01
    MAGNESIUM
     Range 0 to 150 mg/L (as Mg2+)
     Resolution 1 mg/L
     Accuracy (@25°C) ±5 mg/L ±3% of reading
     Method Adaptation of the Calmagite method
     Wavelength 466 nm
     Reagent Code HI-937520-01
    MANGANESE, LOW RANGE
     Range 0 to 300 µg/L (as Mn)
     Resolution 1 µg/L
     Accuracy (@25°C) ±10 µg/L ±3% of reading
     Method Adaptation of the PAN Method
     Wavelength 575 nm
     Reagent Code HI-93748-01
    MANGANESE, HIGH RANGE
     Range 0.0 to 20.0 mg/L (as Mn)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.2 mg/L ±3% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method
     Wavelength 525 nm
     Reagent Code HI-93709-01
    MAPLE SYRUP
     Range 0.00 to 100.00 %T
     Resolution 0.01 %T
     Accuracy (@25°C) ±3% of reading
     Method Direct measure
     Wavelength 560 nm
     Reagent Code HI-93703-57
    MOLYBDENUM
     Range 0.0 to 40.0 mg/L (as Mo6+)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.3 mg/L ±5% of reading
     Method Adaptation of the mercaptoacetic acid method
     Wavelength 420 nm
     Reagent Code HI-93730-01
    NICKEL, LOW RANGE
     Range 0.000 to 1.000 mg/L (as Ni)
     Resolution 0.001 mg/L
     Accuracy (@25°C) ±0.010 mg/L ±7% of reading
     Method Adaptation of the PAN method
     Wavelength 575 nm
     Reagent Code HI-93740-01
    NICKEL, HIGH RANGE
     Range 0.00 to 7.00 g/L (as Ni)
     Resolution 0.01 g/L
     Accuracy (@25°C) ±0.07g/L ±4% of reading
     Method Adaptation of the photometric method
     Wavelength 575 nm
     Reagent Code HI-93726-01
    NITRATE
     Range 0.0 to 30.0 mg/L (as NO3 - N)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.5 mg/L ±10% of reading
     Method Adaptation of the cadmium reduction method
     Wavelength 525 nm
     Reagent Code HI-93728-01
    NITRATE, CHROMOTROPIC ACID
     Range 0.0 to 30.0 mg/L (as NO3 - N)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±1.0 mg/L ±3% of reading
     Method Chromotropic acid method
     Wavelength 410 nm
     Reagent Code HI-93766-50
    NITRITE MARINE
     ULTRA LOW RANGE
     Range 0 to 200 µg/L (as N02-N)
     Resolution 1 µg/L
     Accuracy (@25°C) ±10 µg/L ±4% of reading
     Method Adaptation of the EPA Diazotization method 354.1
     Wavelength 466nm
     Reagent Code HI-764-25
    NITRITE, LOW RANGE
     Range 0 to 600 µg/L (as N02-N)
     Resolution 1 µg/L
     Accuracy (@25°C) ±20 µg/L ±4% of reading
     Method Adaptation of the EPA Diazotization method 354.1
     Wavelength 466nm
     Reagent Code HI-93707-01
    NITRITE, HIGH RANGE
     Range 0 to 150 mg/L (as NO2-)
     Resolution 1 mg/L
     Accuracy (@25°C) ±4 mg/L ±4% of reading
     Method Adaptation of the Ferrous Sulphate method
     Wavelength 575 nm
     Reagent Code HI-93708-01
    NITROGEN, TOTAL LOW RANGE
     Range 0.0 to 25.0 mg/L (as N)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±1.0 mg/L or ±5% of reading
     Method Chromotropic acid method
     Wavelength 420 nm
     Reagent Code HI-93767A-50
    NITROGEN, TOTAL HIGH RANGE
     Range 10 TO 150 mg/L (as N)
     Resolution 1 mg/L
     Accuracy (@25°C) ±3 mg/L or ±4% of reading
     Method Chromotropic acid method
     Wavelength 420 nm
     Reagent Code HI-93767b-50
    OXYGEN, DISSOLVED
     Range 0.0 to 10.0 mg/L (as O2)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.4 mg/L ±3% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
     Wavelength 420 nm
     Reagent Code HI-93732-01
    OXYGEN SCAVENGERS
     (CARBOHYDRAZIDE)
     Range 0.00 to 1.50 mg/L (as Carbohydrazide)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.02 mg/L ±3% of reading
     Method Adaptation of the iron reduction method
     Wavelength 575 nm
     Reagent Code HI-96773-01
    OXYGEN SCAVENGERS
     (DIETHYLHYDROXYLAMINE)(DEHA)
     Range 0 to 1000 µg/L (as DEHA)
     Resolution 1 µg/L
     Accuracy (@25°C) ±5 µg/L ±5% of reading
     Method Adaptation of the iron reduction method
     Wavelength 575 nm
     Reagent Code HI-96773-01
    OXYGEN SCAVENGERS
     (HYDROQUINONE)
     Range 0.00 to 2.50 mg/L (as Hydroquinone)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.04 mg/L ±3% of reading
     Method Adaptation of the iron reduction method
     Wavelength 575 nm
     Reagent Code HI-96773-01
    OXYGEN SCAVENGERS
     (ISO-ASCORBIC ACID)
     Range 0.00 to 4.50 mg/L (as Iso-ascorbic acid)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the iron reduction method
     Wavelength 575 nm
     Reagent Code HI-96773-01
    OZONE
     Range 0.00 to 2.00 mg/L (as O3 )
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.02 mg/L ±3% of reading
     Method Colorimetric DPD Method
     Wavelength 525 nm
     Reagent Code HI-93757-01
    pH
     Range 6.5 to 8.5 pH
     Resolution 0.1pH
     Accuracy (@25°C) ±0.1 pH
     Method Adaptation of the Phenol Red method
     Wavelength 525 nm
     Reagent Code HI-93710-01
    PHOSPHORUS
     MARINE ULTRA LOW RANGE
     Range 0 to 200 µg/L (as P)
     Resolution 1 µg/L
     Accuracy (@25°C) ±5 µg/L ±5% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method
     Wavelength 610 nm
     Reagent Code HI-736-25
    PHOSPHATE, LOW RANGE
     Range 0.00 to 2.50 mg/L (as PO4 3-)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.04 mg/L ±4% of reading
     Method Adaptation of the Ascorbic Acid method
     Wavelength 610 nm
     Reagent Code HI-93713-01
    PHOSPHATE, HIGH RANGE
     Range 0.0 to 30.0 mg/L (as PO4 3-)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±1.0 mg/L ±4% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
     Wavelength 525 nm
     Reagent Code HI-93717-01
    PHOSPHORUS
     REACTIVE LOW RANGE
     Range 0.00 to 1.60 mg/L (as P)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.05 mg/L or ±4% of reading
     Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
     Wavelength 610 nm
     Reagent Code HI-93758A-50
    PHOSPHORUS
     REACTIVE HIGH RANGE
     Range 0.0 to 32.6 mg/L (as P)
     Resolution 0.1 mg/L
     Accuracy (@25°C) ±0.5 mg/L or ±4% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method
     Wavelength 420 nm
     Reagent Code HI-93763A-50
    PHOSPHORUS, ACID HYDROLYZABLE
     Range 0.00 to 1.60 mg/L (as P)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.05 mg/L or ±5% of reading
     Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
     Wavelength 610 nm
     Reagent Code HI-93758B-50
    PHOSPHORUS
     TOTAL LOW RANGE
     Range 0.00 to 1.15 mg/L (as P)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.05 mg/L or ±6% of reading
     Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
     Wavelength 610 nm
     Reagent Code HI-93758c-50
    PHOSPHORUS
     TOTAL HIGH RANGE
     Range 0.00 to 32.6 mg/L (as P)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.05 mg/L or ±5% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method
     Wavelength 420 nm
     Reagent Code HI-93763B-50
    POTASSIUM, LOW RANGE
     Range 0.0 to 20.0 mg/L (as K)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±2 mg/L ±7% of reading
     Method Adaptation of the Turbidimetric Tetraphenylborate method
     Wavelength 466 nm
     Reagent Code HI-93750-01
    POTASSIUM, MEDIUM RANGE
     Range 10 to 100 mg/L (as K)
     Resolution 1 mg/L
     Accuracy (@25°C) ±10 mg/L ±7% of reading
     Method Adaptation of the Turbidimetric Tetraphenylborate method
     Wavelength 466 nm
     Reagent Code HI-93750-01
    POTASSIUM, HIGH RANGE
     Range 20 to 200 mg/L (as K)
     Resolution 1 mg/L
     Accuracy (@25°C) ±20 mg/L ±7% of reading
     Method Adaptation of the Turbidimetric Tetraphenylborate method
     Wavelength 466 nm
     Reagent Code HI-93750-01
    SILICA, LOW RANGE
     Range 0.00 to 2.00 mg/L (as SiO2 )
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method
     Wavelength 610 nm
     Reagent Code HI-93750-01
    SILICA, HIGH RANGE
     Range 0 to 200 mg/L (as SiO2 )
     Resolution 1 mg/L
     Accuracy (@25°C) ±1 mg/L ±5% of reading
     Method Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2
     Wavelength 466 nm
     Reagent Code HI-96770-01
    SILVER
     Range 0.000 to 1.000 mg/L (as Ag)
     Resolution 0.001 mg/L
     Accuracy (@25°C) ±0.020 mg/L ±5% of reading
     Method Adaptation of the PAN method
     Wavelength 575 nm
     Reagent Code HI-93737-01
    SULPHATE
     Range 0 to 150 mg/L (as SO42-)
     Resolution 1 mg/L
     Accuracy (@25°C) ±5 mg/L ±3% of reading
     Method Sulphate is precipitated with barium chloride crystals
     Wavelength 466 nm
     Reagent Code HI-93751-01
    SURFACTANTS, ANIONIC
     Range 0.00 to 3.50 mg/L (as SDBS)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.04 mg/L ±3% of reading
     Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
     Wavelength 610 nm
     Reagent Code HI-95769-01
    ZINC
     Range 0.00 to 3.00 mg/L (as Zn)
     Resolution 0.01 mg/L
     Accuracy (@25°C) ±0.03 mg/L ±3% of reading
     Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
     Wavelength 575 nm
     Reagent Code HI-93731-01

    Product Literature

    literature - PDF

    Hanna Instruments Literature

    Questions & Answers

    Got a question to ask? Use this form to submit your question.
    Question will be displayed after moderation.
    Name* Product Question*
    No questions yet?
    Don 't be shy, be the first to ask.